10 HOW TO USE TIME CODE
10-3 TIME CODE RECORDING
Recording the time code data output from the external time code generator
Externally generated time code can be recorded after being regenerated with the time code data output from the
10 HOW TO USE TIME CODE
10-4 TIME CODE PLAYBACK
Time code is output through the rear panel [TC OUT] and [VIDEO OUT] connectors during playback. VITC time code with the time code data superimposed on the video signal is output through the [VIDEO
AUDIO INPUT / AUDIO MONITOR SELECT
SDI CH1 CH2 CH3 CH4
AES/EBUL CH1 CH2 CH3 CH4
ANALOGR CH1 CH2 CH3 CH4
| VIDEO CASSETTE RECORDER |
|
| |||
|
|
|
| POWER |
|
|
SIF |
|
|
|
|
|
|
LINE |
|
| ON | I |
|
|
CPN | COMPONENT DIGITAL |
| OFF | O |
|
|
|
|
|
|
| ||
| Variable Motion |
|
|
|
|
|
|
| TIME CDOE |
|
|
| |
| DF | INT | FREE PRESET |
|
| |
| NDF EXT | REC | REGEN |
|
| |
| RF HID GND | OFF | 8 | ON |
|
|
| SERVICE USE ONLY | ON | 4 | OFF |
|
|
|
| CF | (625) | ON SCREEN |
|
|
|
|
|
|
| TIME CDOE | |
|
|
|
| DF | INT | FREE PRESET |
| Front sub panel |
|
|
|
| REC REGEN |
|
|
|
| NDF | EXT |
|
|
|
|
|
|
| [COUNTER] button |
| ||||
|
|
|
|
|
|
|
|
|
|
| VIDEO CASSETTE RECORDER |
|
AUDIO INPUT / AUDIO MONITOR SELECT |
|
|
|
|
|
|
| POWER | ||||
SDI | CH1 | CH2 | CH3 | CH4 | SIF |
|
|
|
|
|
|
|
AES/EBU | CH1 | CH2 | CH3 | CH4 | LINE |
|
|
|
|
| ON | I |
L |
|
|
|
|
|
|
| |||||
ANALOG | CH1 | CH2 | CH3 | CH4 | CPN |
|
| COMPONENT DIGITAL |
|
| OFF | O |
R |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Variable Motion |
|
| |||
CH1 | CH2 |
| CH3 | CH4/TRACKING |
|
|
|
|
|
|
|
|
|
|
|
|
| CTL TC UB DF SERVO CF GEN 16:9 AP | 525 | CONDITION | COUNTER | RESET | VCON | REMOTE |
|
|
|
|
|
| AUTO OFF P.READ V.VAR PB/EE REMOTE | 625 |
| UB |
|
|
|
|
|
|
|
|
|
|
|
| MENU | SET | HOLD | PB |
|
|
|
|
|
|
|
|
| PB/EE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| STILL |
|
|
|
|
| H | M |
| S |
| F |
|
|
|
|
|
|
|
|
| ASSEM | VIDEO | DA1 | DA2 | DA3 | DA4 | EJECT | REC | PLAY | PAUSE/STILL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| X1 | |
PHONES | CH1 | CH2 REC CH3 | CH4 | TRACKING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| IN | ENTRY | OUT | INSERT |
| TC | TOP |
| VIDEO | AUDIO |
|
|
|
| PULL FOR VARIABLE |
| METER MODE | CANCEL PREVIEW | AUTO EDIT | PREROLL | STAND BY | REW | STOP | FF |
|
| ||
PULL |
|
|
|
|
|
|
|
|
|
|
|
|
|
| PULL |
RELEASE |
| PLAY |
| SHIFT |
| REVIEW |
|
| USER | SERVO/SYS | TIME CODE | ON SCREEN | OTHERS |
| RELEASE |
|
|
|
|
|
| REV | FWD |
[PLAY] button
Notes
●
Automatically selected according to the mode of the received time code (Drop Frame or
●Regeneration operation
•When time code is being regenerated with input time code, the
●In the Play mode, time code regeneration is based on the playback time code value.
●Inserting time code
If only time code data is being inserted, record it on the main time code. It is not possible to insert it in the sub time code.
1.Front sub panel switch setting
●Select the External Time Code Generator mode by setting the [INT/EXT] switch to “EXT”.
The [FREE/REC] and [PRESET/REGEN] switch settings are not necessary.
●Select the Counter Display or
2.Menu switch setting
●Select the external time code to be regenerated.
●Menu switch No. 409 <EXT REGEN TC> (Initial setting: LTC (0))
LTC (0): Regenerates the LTC time code input through the rear panel [TC IN] connector.
Input LTC time code should be regenerated (matched in terms of sync and phase) with video signals. Make sure you input an external sync signal to the feeding equipment.
VITC (1): Regenerates the VITC time code superimposed on the video signal input through the rear panel VIDEO IN connector.
●User bit data selection
●Menu switch No. 457 <UB PRESET AUTO> (initial setting OFF (0))
OFF (0): User bits regenerated by the time code generator of this unit is recorded.
ON (1): The user bit auto preset function is activated and the user bit data stored in the
●Select the sub time code.
●Menu switch No. 450 <SUB TC (VITC) REC> (Initial setting: ON(1))
OFF (0): “00:00:00:00” is always recorded on the sub time code.
ON (1): Records the input VITC time code in the sub time code.
3.Record the time code.
Press the [PLAY] button while pressing the [REC] button. [The selected time code will be recorded.
●When you are using this deck as a player, the recording time code may not be regenerated when you output embedded audio (SERIAL V/A OUT) signals to the
●
Sub time code is displayed with the main time code when menu switch No. 451
<VITC OUT SELECT> is set to “SUB TC (0)”.
Setting
1.Front panel switch setting
●Select a Counter Display mode to TC or UB with the [COUNTER] and [SHIFT] buttons.
2.Menu switch setting
●For VITC time code output, select a line to be added to the video signal.
●Menu switch No. 400 <VITC
●Menu switch No. 401 <VITC
●Select VITC time code output through the [VIDEO OUT] connector. Menu switch No. 451 <VITC OUT SELECT>
SUB TC (0) | : Outputs the VITC time code recorded in the sub time code. |
TC (1) | : Outputs the time code recorded in the main time code. |
OFF | : VITC time code is not output from the [VIDEO OUT] |
| connector. |
Factory setting : TC (1) |
●Select the Time Code Output mode during search. Menu switch No. 452 <SEARCH LTC>
OFF (0) | : Outputs time code through the [TC OUT] connector during search |
| at X1. |
ON (1) | : Outputs time code through the [TC OUT] connector during search |
| at all speeds. Continuous time code is not available. |
3.Play back the time code. Press the [PLAY] button.
[The selected time code is played back.
TCR or UBR is shown with the
●LTC time code is output from the [TC OUT] connector.
●Main or sub time code selected with menu switch No. 451 <VITC OUT SELECT> is superimposed on video signals and output to the line selected with menu switch No. 400 and No. 401 from the [VIDEO OUT] connector.
100 | 101 |