JVC BR-D95U specifications Changing the registered menu switch setting

Page 18

4 MENU SWITCH SETTING

4-6 USER PAGE REGISTRATION/CHANGE/DELETE (User page function)

Up to five menu switch settings can be registered on the user page (User Page function).

The User Page function allows you to register frequently used menu switches for quicker access when you want

4 MENU SWITCH SETTING

4-6 USER PAGE REGISTRATION/CHANGE/DELETE (User page function) (con't)

to change the settings.

 

 

Procedure

Menu switch setting display

Registering a menu switch on the User Page

 

Counter

display

 

On-screen display

 

 

 

 

 

 

 

 

 

 

 

 

 

301:DIRECT SEARCH

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

H

 

M

 

 

 

 

 

S

 

 

 

005:AUTO TRACKING

 

 

 

 

 

 

F

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

002:OPERATION LOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Procedure

Changing the registered menu switch setting

1. Press the [MENU] button to call up the menu

display mode.

HMSF

HMSF

HMSF

HMSF

HMSF

300: DIRECT EJECT ON 301:DIRECT SEARCH ON 302:BACK SPACE ON 307:PAUSE/STILL/STP TIME 5MIN 311:AUTO PLAY OFF

300: DIRECT EJECT ON 301:DIRECT SEARCH ON 302:BACK SPACE ON 307:PAUSE/STILL/STP TIME 5MIN 311:AUTO PLAY OFF

Hold the [SET] button.

MENU SET

User Page display screen U01:(FOR USER) U02:(FOR USER) U03:(FOR USER) U04:(FOR USER) U05:(FOR USER)

Release the [SET] button.

301:DIRECT SEARCH ON U02:(FOR USER)

U03:(FOR USER)

U04:(FOR USER)

U05:(FOR USER)

1.Call up the menu switch setting screen. Press the [MENU] button.

[ Call up the menu screen on the counter display and on-screen display. When the top menu is displayed, turn the jog dial to set to the

menu switch setting screen.

2.Turn the jog dial to select the menu switch you want to register.

Menu switch selection is also possible using the ÒDirect Access functionÓ.

3.Press and hold the [SET] button.

During setting, ÒSETÓ blinks on the counter display and ÒMENU SETÓ blinks on the on-screen display.

While still keeping the [SET] button pressed (even after the [SET] indication goes out), execute the next operation.

4.

When the menu switch setting screen appears, turn

 

the jog dial to access the User Page screen.

 

*Memo: The User Page screen can be displayed

 

using the Direct Access function. See

 

page 33.

5.

Select the line you want to register on the User

 

Page screen.

 

While keeping the [SET] button pressed, turn the

 

jog dial to select the line number (U01 - U05) you

 

want to register.

 

[ The line number is displayed on the counter

 

display; the line number blinks on the on-

 

screen display.

6.

Release the [SET] button.

 

[ The menu switch setting is displayed and the

 

selected line is registered on the User Page.

7.

To register more items, repeat steps 2 through 6.

 

Registration of up to five items is possible.

8.

To end User Page registration, press the

 

[MENU] button. The normal display will be

 

restored.

¥When steps 2 through 6 are performed on an already registered line, the new menu switch setting replaces the original line.

¥Registered lines on the User Page can be moved. Select the menu switch you want to move and follow steps 3 through 6.

¥Items D95,00A to 00E on the top menu and the DH:DRUM HOUR menu switch cannot be registered on the User Page.

¥The menu registered on the User Page is reset when the unit is initialized (with menu switch 00A).

 

 

 

 

U04:(FOR USER)

 

 

 

 

U05:(FOR USER)

 

 

 

 

301:DIRECT SEARCH

 

 

 

 

ON

 

 

 

 

005:AUTO TRACKING

H

M

S

F

OFF

 

 

 

 

002:OPERATION LOCK

 

 

 

 

OFF

 

 

 

 

U04:(FOR USER)

 

 

 

 

U05:(FOR USER)

H

M

S

F

 

 

 

 

 

MENU SET

2.

Select the menu switch item to be changed

 

with the jog dial.

 

The selected menu switch number blinks on the

 

on-screen display.

 

The menu switch number changes on the

 

counter display.

3.

Select the setting value by turning the jog dial

 

while pressing the [SEARCH] button.

 

The counter display shows the setting value.

4.

To change additional items, repeat steps 2 to 3.

5.

Press the [SET] button to register the new

 

setting.

 

[ During setting, ÒSETÓ blinks on the counter

 

display and ÒMENU SETÓ blinks on the on-

 

screen display. When setting is complete, the

 

normal screen is restored.

34

35

Image 18
Contents BR-D95U This instruction book is made from 100% recycled paperImportant Safeguards This unit should be used with 120 V AC onlyPort Cable Length Main Features ContentsOutline MaintenanceIntroduction Other FunctionsPrecautions Head CleaningVideo Cassette Front Panel Setting buttons  Menu button Video Input indicatorsAudio signal select buttons $PB PB/EE button PAUSE/STILL SUB Panel Rear PanelCounter Display ON-SCREEN Display Connections Operation mode display in the VariableMUTING/CONDITION Alarm display Input ConnectionsControl System Connections Editing remote control connectionOutput Connections Composite OUTMenu Display Modes Menu Switch Setting00A Menu Setting 00F Fixed Time EntryVideo Signal System Selection PALAccess Saving and Calling UP Menu Switch SettingsEnabling the Direct Access function ÒonóChanging the registered menu switch setting Activating the menu switch lock function Erasing all registered items on the UserErasing registered items one at a time Recording Current Adjustment Activating the recording current adjustment functionMenu Switch Setting Details Menu Switch ListFunctions enclosed Are not available on the PAL system Menu Switch Setting Content Normal ECC ModeVD REC Signal Slow Picture FrameExtra Line PB Line SetupWide MutingVblank Ycomb OFF on OFF WITH21 VblankFactory setting CH2 AT 2CHCH1 0DB CH3Silence PB/EE ModeSetting PAUSE/STILL SEC STP/TIME15SEC Diag AT OFF Power on0SEC StillTime Code Swap Mode DisableSafety PARA-RUN OFFCF Flag Reply Synchro Disable Nization EnableRegen Mode FLDRemain Enable UB Preset OFF AutoMode ASM INS 0FF EXT LTC Regen TC VitcOperation Mode Lock PreparationStandby ON/OFF Loading the cassette Turn the Power switch onRemove the cassette from the slot Precautions Load the cassetteInput Video and Audio Signal Selection RecordingPreparation for Recording Audio Monitor Output Signal Selection Audio Record Level AdjustmentBasic Recording Operations Digital Audio Signal INPUT/OUTPUT PlaybackPreparation for Playback Manual audio playback level adjustment Audio Playback Level AdjustmentAudio Playback Level Lock mode Basic Playback OperationsAdjust until the tracking meter level reaches the maximum Play volume controlSet menu switch No Auto Tracking to OFF Manual Tracking AjustmentError Correction Simplified Playback Speed Adjustment FunctionAudio V. Fade Function To stop search operation Shuttle SEARCH/JOG OperationVariable Slow Playback Jog operation Turn the inner jog dialProgram Playback 11 FF, REW and Counter Memory Functions User SettingOther Functions Extra Line Data RECORDING/PLAYBACKExtra line data playback Signals. Factory settingAuto When video signals are output, extra line Line recordingSimultaneous Operation Fixed Time CUE UP FunctionMulti CUE-UP Function Engage the Multi Cue-Up modeQuit the Multi Cue mode Cue Operation buttons DisplayStriping REC Menu Striping RECFront sub panel switches for time code setting HOW to USE Time CodeTime Code Initial Setting Preset Time Code DisplayTime Code Recording Front sub panel switch setting Time Code PlaybackRecord the time code Time Code Switch Setting for Editing SUB Time Code Recording and PlaybackRecording EditingAssemble editing Insert editing PlaybackColor Frame Servo Setting Editing procedurePreparation Editing mode selection Swap EditingEdit point entry Review check Preview editingEditing actual Correcting the edit pointAudio Split Editing Other FunctionEditing with the PRE-READ Function Manual EditingThat allows you to bypass the frame memory Editing System Phase AdjustmentExample of editing system configuration Refer toRepeat steps 2 to 3 to adjust other items Select the adjustment item by turning the jog dialAdjustment items on screen can be selected with the cursor Item belowAdjustment Basic Table Dubbing Loop Function122 JVC-1 Table0A ACK 0B NAK3F Stop Key Flag ResetOut Flag Reset CueUp With DataExecutes Auto Edit on the VCR B6 Rev Shuttle KeyC0 Auto Edit Key C1 Preview Key Basic TableE7 Timer Mode Select E4 Out Data PresetE6 Preroll TimePreset Basic Table E5 Edit PresetFA Rec/DubRequest F6 JVC OnF7 Basic Table On FB VTR INDSpeed/data correspondence table Current timer mode For the current timer modeTimer mode Bit-3 Auto modeDATA0 0A DATA0 0BDATA0 0F DATA0 1BDATA0 0E DATA0 1FDATA0 1D Troubleshooting On-screen displayCode On-screen display Behavior and actions to be taken Troubles not to be Warned by IndicatorsSymptoms Cause Not operable Remote button is set to Remote ActionOptional Accessories AppendixSpecifications Unit mm150