JVC BR-D95U specifications Digital Audio Signal INPUT/OUTPUT, Preparation for Playback

Page 38

7 RECORDING

7-6 DIGITAL AUDIO SIGNAL INPUT/OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO CASSETTE RECORDER

BR-D95U

 

AUDIO INPUT / AUDIO MONITOR SELECT

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

SDI

CH1

CH2

CH3

CH4

SIF

 

 

 

 

 

 

 

 

 

 

 

 

 

AES/EBU

CH1

CH2

CH3

CH4

LINE

 

 

 

 

 

 

 

 

 

 

ON

I

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

ANALOG

CH1

CH2

CH3

CH4

CPN

 

 

 

 

 

COMPONENT DIGITAL

 

 

 

OFF

O

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable Motion

 

 

 

 

CH1

CH2

CH3

 

CH4/TRACKING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTL TC UB DF SERVO CF GEN 16:9 AP

525

CONDITION

 

COUNTER

RESET

VCON

REMOTE

 

 

 

 

 

 

 

 

AUTO OFF P.READ V.VAR PB/EE REMOTE

625

 

 

UB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

SET

HOLD

PB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PB/EE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STILL

 

 

 

 

 

 

 

 

H

 

M

S

F

 

 

 

 

 

 

 

 

 

 

 

 

 

ASSEM

VIDEO

DA1

DA2

DA3

DA4

EJECT

REC

PLAY

PAUSE/STILL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-1

X1

PHONES

CH1

CH2

REC CH3

 

CH4

TRACKING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

ENTRY

OUT

INSERT

 

TC

TOP

 

VIDEO

AUDIO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PULL FOR VARIABLE

 

METER MODE

CANCEL PREVIEW

AUTO EDIT

PREROLL

STAND BY

REW

STOP

FF

 

 

PULL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PULL

RELEASE

 

 

PLAY

 

 

SHIFT

 

REVIEW

 

 

USER

SERVO/SYS

TIME CODE

ON SCREEN

OTHERS

 

RELEASE

 

 

 

 

 

 

 

 

REV

FWD

8 PLAYBACK

8-1 PREPARATION FOR PLAYBACK

 

 

 

 

 

 

 

 

 

2

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO CASSETTE RECORDER

BR-D95U

 

AUDIO INPUT / AUDIO MONITOR SELECT

 

 

 

 

 

 

 

POWER

 

SDI

CH1

CH2

CH3

CH4

SIF

 

 

 

 

 

 

 

1

AES/EBU

CH1

CH2

CH3

CH4

LINE

 

 

 

 

 

ON

I

L

 

 

 

 

 

 

 

ANALOG

CH1

CH2

CH3

CH4

CPN

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

COMPONENT DIGITAL

 

 

OFF

O

 

 

 

 

 

 

 

 

Variable Motion

 

 

 

CH1

CH2

 

CH3

CH4/TRACKING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTL TC UB DF SERVO CF GEN 16:9 AP

525

CONDITION

COUNTER

RESET

VCON

REMOTE

 

 

 

 

 

 

 

AUTO OFF P.READ V.VAR PB/EE REMOTE

625

 

UB

 

 

 

 

 

 

 

 

 

 

 

 

 

MENU

SET

HOLD

PB

 

 

 

 

 

 

 

 

 

 

PB/EE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STILL

 

 

 

 

 

H

M

 

S

 

F

 

 

 

 

 

 

 

 

 

ASSEM

VIDEO

DA1

DA2

DA3

DA4

EJECT

REC

PLAY

PAUSE/STILL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-1

X1

PHONES

CH1

CH2 REC CH3

CH4

TRACKING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

ENTRY

OUT

INSERT

 

TC

TOP

 

VIDEO

AUDIO

 

 

 

 

PULL FOR VARIABLE

 

METER MODE

CANCEL

PREVIEW

AUTO EDIT

PREROLL

STAND BY

REW

STOP

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

PULL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PULL

RELEASE

 

PLAY

 

SHIFT

 

REVIEW

 

 

USER

SERVO/SYS

TIME CODE

ON SCREEN

OTHERS

 

RELEASE

 

 

 

 

 

 

REV

FWD

 

When this unit is

 

synchronized externally

Counter mode

 

 

 

 

REMOTE indicator

 

 

 

 

(when using the

indicators

 

 

 

 

 

 

 

 

remote control unit)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

525 CONDITION

 

CTL TC UB

 

GEN

 

 

 

 

 

 

 

REMOTE

625

 

 

 

 

This unit does not execute emphasis recording.

When digital audio signals containing emphasis information are input to this unit, this unit automatically de-emphasizes these signals before recording. The emphasis function is always OFF when digital audio signals are recorded on this unit.

Note:

Analog or digital audio output may not be clear when a tape whose audio has been recorded on its audio channels with emphasis both ON and OFF is played back on the BR-D85U/D80U/D51U/D50U/D750U/D350U

DIGITAL S VCR.

A sampling rate converter is provided for the BR-D95U’s AES/EBU input. This enables input of both professional-standard and consumer-standard digital signals with sampling frequencies of 48 kHz, 44.1 kHz and 32 kHz. However, the following signals are muted and cannot be recorded. In this case, the [AUDIO INPUT/AUDIO MONITOR SELECT] indicator blinks.

Professional mode, CCIT J17

Consumer mode, data mode ON

Consumer mode, 4-channel mode

Digital audio signal output status bit

The sampling rate converter converts the digital audio signal output status bit from this unit to professional mode signals with a sampling frequency of 48 kHz and emphasis OFF regardless of the type of input signals.

Front panel switch setting

1.Select the audio monitor output.

Select the audio monitor output from the rear panel [AUDIO MONITOR OUT] connectors or the front panel [PHONES] jack.

For the selection procedure, refer to “Audio monitor output selection” on page 70.

2.Set the tape counter mode.

Set the time data to be shown on the counter display and the on-screen display. “CTL”, “TC” or “UB” will be shown on the counter display.

3.Engage the Remote mode.

To operate this unit locally, press the [REMOTE] button so that the [REMOTE] indicator on the counter display goes out.

To operate this unit via the RS-422 or RS-232C serial remote interface, press the [REMOTE] button so that the [REMOTE] indicator lights.

Menu switch setting

Set the menu switches as required.

Reference sync signal items

Select the reference sync system.

No. 003 <SYNC SELECT> ..... Page 43

Set to “EXT” to synchronize with an external sync signal.

Tracking adjustment selection

Auto tracking/manual tracking selection No. 005 “AUTO TRACKING” .... Page 43

Video items

Component video output level selection (NTSC only)

No. 104 <CPN LEV./SETUP (525)> ... Page 44

Error correction mode selection No. 112 <ECC MODE> ... Page 45

Audio items

Audio V. fade function selection

Select whether audio noise in transitions should be reduced or not.

No. 214 <PBV. FADE> ..... Page 50

Audio output level adjustment mode selection Select automatic or manual adjustment.

No. 216 <AUD PB VOLUME MODE 1> ... Page 51

Set the output to CH3 and CH4 when playing back a tape with two-channel audio (CH1 and CH2).

No. 223 CH3/4 OUT SEL AT 2CH ... Page 52

Audio output level setting

Select the reference output level for the audio output connectors (CH1 to CH4 ) from +4 dB, 0 dB and -6 dB.

No. 228 to No. 231 <AUDIO OUT LEVEL CH1 — CH4> ... Page 52

Audio monitor output level setting

Select the reference output level for the L and R audio monitor output channels from +4 dB, 0 dB and -6 dB.

No. 232 to No. 233 <AUDIO MON LEVEL LCH — RCH>

Auto Play mode selection

Set whether the tape is automatically played back from the beginning or not.

Output picture selection when playback starts Select the output picture that will be displayed until the servo has stabilized after starting play back.

No. 368 <STARTING PIC FREEZE> ... Page 57

Setting the video signal vertical blanking period masking

No. 601 <V. BLANK MASK> ..... Page 64

74

75

Image 38
Contents BR-D95U This instruction book is made from 100% recycled paperImportant Safeguards This unit should be used with 120 V AC onlyPort Cable Length Main Features ContentsOutline MaintenanceIntroduction Other FunctionsVideo Cassette PrecautionsHead Cleaning Front Panel Setting buttons  Menu button Video Input indicatorsAudio signal select buttons $PB PB/EE button PAUSE/STILL SUB Panel Rear PanelCounter Display ON-SCREEN Display Connections Operation mode display in the VariableMUTING/CONDITION Alarm display Input ConnectionsControl System Connections Editing remote control connectionOutput Connections Composite OUTMenu Display Modes Menu Switch Setting00A Menu Setting 00F Fixed Time EntryVideo Signal System Selection PALAccess Saving and Calling UP Menu Switch SettingsEnabling the Direct Access function ÒonóChanging the registered menu switch setting Erasing registered items one at a time Activating the menu switch lock functionErasing all registered items on the User Recording Current Adjustment Activating the recording current adjustment functionFunctions enclosed Are not available on the PAL system Menu Switch Setting DetailsMenu Switch List Menu Switch Setting Content Normal ECC ModeVD REC Signal Slow Picture FrameExtra Line PB Line SetupWide MutingVblank Ycomb OFF on OFF WITH21 VblankFactory setting CH2 AT 2CHCH1 0DB CH3Silence PB/EE ModeSetting PAUSE/STILL SEC STP/TIME15SEC Diag AT OFF Power on0SEC StillTime Code Swap Mode DisableSafety PARA-RUN OFFCF Flag Reply Synchro Disable Nization EnableRegen Mode FLDRemain Enable UB Preset OFF AutoMode ASM INS 0FF EXT LTC Regen TC VitcOperation Mode Lock PreparationStandby ON/OFF Loading the cassette Turn the Power switch onRemove the cassette from the slot Precautions Load the cassette Preparation for Recording Input Video and Audio Signal Selection Recording Audio Monitor Output Signal Selection Audio Record Level AdjustmentBasic Recording Operations Preparation for Playback Digital Audio Signal INPUT/OUTPUTPlayback Manual audio playback level adjustment Audio Playback Level AdjustmentAudio Playback Level Lock mode Basic Playback OperationsAdjust until the tracking meter level reaches the maximum Play volume controlSet menu switch No Auto Tracking to OFF Manual Tracking AjustmentAudio V. Fade Function Error CorrectionSimplified Playback Speed Adjustment Function To stop search operation Shuttle SEARCH/JOG OperationVariable Slow Playback Jog operation Turn the inner jog dialProgram Playback 11 FF, REW and Counter Memory Functions User SettingOther Functions Extra Line Data RECORDING/PLAYBACKExtra line data playback Signals. Factory settingAuto When video signals are output, extra line Line recordingSimultaneous Operation Fixed Time CUE UP FunctionMulti CUE-UP Function Engage the Multi Cue-Up modeQuit the Multi Cue mode Cue Operation buttons DisplayStriping REC Menu Striping RECFront sub panel switches for time code setting HOW to USE Time CodeTime Code Initial Setting Preset Time Code DisplayTime Code Recording Record the time code Front sub panel switch settingTime Code Playback Time Code Switch Setting for Editing SUB Time Code Recording and PlaybackRecording EditingAssemble editing Insert editing PlaybackPreparation Color Frame Servo SettingEditing procedure Edit point entry Editing mode selectionSwap Editing Review check Preview editingEditing actual Correcting the edit pointAudio Split Editing Other FunctionEditing with the PRE-READ Function Manual EditingThat allows you to bypass the frame memory Editing System Phase AdjustmentExample of editing system configuration Refer toRepeat steps 2 to 3 to adjust other items Select the adjustment item by turning the jog dialAdjustment items on screen can be selected with the cursor Item belowAdjustment Basic Table Dubbing Loop Function122 JVC-1 Table0A ACK 0B NAK3F Stop Key Flag ResetOut Flag Reset CueUp With DataExecutes Auto Edit on the VCR B6 Rev Shuttle KeyC0 Auto Edit Key C1 Preview Key Basic TableE7 Timer Mode Select E4 Out Data PresetE6 Preroll TimePreset Basic Table E5 Edit PresetFA Rec/DubRequest F6 JVC OnF7 Basic Table On FB VTR INDSpeed/data correspondence table Current timer mode For the current timer modeTimer mode Bit-3 Auto modeDATA0 0A DATA0 0BDATA0 0F DATA0 1BDATA0 0E DATA0 1FDATA0 1D Code TroubleshootingOn-screen display On-screen display Behavior and actions to be taken Troubles not to be Warned by IndicatorsSymptoms Cause Not operable Remote button is set to Remote ActionOptional Accessories Appendix150 SpecificationsUnit mm