1750

Operators Manual

Automatic disturbance capture

The Recorder uses an automatic, self-learning threshold routine, which means you do not have to set any event threshold limits before you start recording. You detect and display power quality events (disturbances) using the Power Analyze software on a PC after the event has been captured. You define thresholds for events after data is stored on the PC. This is called the "event detector" in the software. It does not make permanent changes to the data file, so you can experiment with different thresholds after the fact without worrying about losing data.

With these features, there is little else required to set up and start recording the data to conduct a power quality survey. Should you want to extensively analyze collected data, the procedures described later in this manual review the transfer of data from the Recorder to the PDA, and finally to a PC. Data may then be analyzed using Power Analyze on a PC. Extensive online help is provided in the Power Analyze software on the product CD shipped with the Recorder.

Contacting Fluke

To contact Fluke, call one of the following telephone numbers:

Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)

Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)

Canada: 1-800-36-FLUKE (1-800-363-5853)

Europe: +31 402-675-200

Japan: +81-3-3434-0181

Singapore: +65-738-5655

Anywhere in the world: +1-425-446-5500

Or, visit Fluke's website at www.fluke.com.

To register your product, visit http://register.fluke.com.

To view, print, or download the latest manual supplement, visit

http://us.fluke.com/usen/support/manuals.

To contact Technical Support: fpqsupport@fluke.com or 888-257-9897

2

Image 10
Contents 1750 Limited Warranty and Limitation of Liability Table of Contents 1750 List of Tables 1750 List of Figures 1750 Power Recorder IntroductionContacting Fluke Safety Information XW WarningAccessories Symbols MeaningFeatures Fluke 1750 Power RecorderInput Terminals and Controls Applying the Front Panel Decal Applying the Front Panel DecalConnecting the Supplemental Ground Terminal Installing the Software Charging the PDA BatteryInstalling Power View on the PDA Installing Power Analyze PC System Requirement for Power AnalyzeLanguage Selection Installing the Power Recorder at a Facility Work FlowInstalling the Recorder Connecting the Recorder to the WiringVerifying Your Connection Finishing UPPower Type Diagrams Managing Recorded DataExample Branch circuit at an outlet One-Phase IT No Neutral One-Phase Split Phase GND Three-Phase Delta Three-Phase IT Three-Phase High Leg Example a variant of power transformer winding type Element Delta ØC/L3 ØB/L2 Communicating with the Recorder Using Power View Connecting to the RecorderNavigating in Power View on the PDA Power View MenusIcons on the Menu Bar Menu Tree FlukeHome Screen Azd113.bmp Downloading Data and Erasing Memory Azd117.bmp Azd108s.bmp Azd109s.bmp Viewing Live Data Scope ScreenMeter Screen Phasor ScreenHarmonics Screen Trend ScreenSetting Up the Recorder Viewing PhasesSetup screen shows setup options Setting the Clock Probe DetectSetting the IP Address Adding a Measurement DescriptionConfigure Nominal Power Values Using Phase SwapSetting the Volts and Current Ratio Assign Recorder Name and PasswordAzd132.bmp Change Display Language and Phase Identifier Working with AnnotationsAzd137.bmp Using Image or Voice Annotations Cleaning and Maintenance Turn off the RecorderRegulatory Information for Wireless Communication Synchronization and Sampling General SpecificationsInput Specifications Voltage and Current MeasurementsTransient Voltage Impulse Power and PF MeasurementVoltage and Current Measurement Accuracy Dip Sag and Swell MeasurementsExternal Interface Specifications Environmental and Safety Specifications