Fluke 1750 specifications Turn off the Recorder, Cleaning and Maintenance

Page 56

1750

Operators Manual

file into the synchronization folder on your PDA, so that it will be automatically transferred into the sync folder on the PC the next time you dock the PDA.

Turn off the Recorder

The Recorder always has the UPS enabled to allow a 5-minute pass through time on a voltage interruption. When you pack the Recorder for transport, you have the option to shut down the Recorder and disable the UPS before unplugging the power cord.

To turn off the Recorder:

1.Select Menu>Tools>1750 Shut down...

2.Confirm the warning message.

3.Wait until the Power LED is solid green. The power cord can be safely unplugged.

azd143.bmp

Cleaning and Maintenance

The Recorder contains no user serviceable parts. Contact an Authorized Fluke Service Center for repair. Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.

48

Image 56
Contents 1750 Limited Warranty and Limitation of Liability Table of Contents 1750 List of Tables 1750 List of Figures 1750 Power Recorder IntroductionContacting Fluke Safety Information XW WarningAccessories Symbols MeaningFeatures Fluke 1750 Power RecorderInput Terminals and Controls Applying the Front Panel Decal Applying the Front Panel DecalConnecting the Supplemental Ground Terminal Installing Power View on the PDA Charging the PDA BatteryInstalling the Software Language Selection PC System Requirement for Power AnalyzeInstalling Power Analyze Installing the Power Recorder at a Facility Work FlowInstalling the Recorder Connecting the Recorder to the WiringVerifying Your Connection Finishing UPPower Type Diagrams Managing Recorded DataExample Branch circuit at an outlet One-Phase IT No Neutral One-Phase Split Phase GND Three-Phase Delta Three-Phase IT Three-Phase High Leg Example a variant of power transformer winding type Element Delta ØC/L3 ØB/L2 Communicating with the Recorder Using Power View Connecting to the RecorderNavigating in Power View on the PDA Power View MenusIcons on the Menu Bar Menu Tree FlukeHome Screen Azd113.bmp Downloading Data and Erasing Memory Azd117.bmp Azd108s.bmp Azd109s.bmp Viewing Live Data Scope ScreenMeter Screen Phasor ScreenHarmonics Screen Trend ScreenSetting Up the Recorder Viewing PhasesSetup screen shows setup options Setting the Clock Probe DetectSetting the IP Address Adding a Measurement DescriptionConfigure Nominal Power Values Using Phase SwapSetting the Volts and Current Ratio Assign Recorder Name and PasswordAzd132.bmp Change Display Language and Phase Identifier Working with AnnotationsAzd137.bmp Using Image or Voice Annotations Cleaning and Maintenance Turn off the RecorderRegulatory Information for Wireless Communication General Specifications Input SpecificationsSynchronization and Sampling Voltage and Current MeasurementsPower and PF Measurement Voltage and Current Measurement AccuracyTransient Voltage Impulse Dip Sag and Swell MeasurementsExternal Interface Specifications Environmental and Safety Specifications