Fluke 1750 specifications Three-Phase High Leg

Page 29

Power Recorder

Power Type Diagrams

ØC/L3

ØB/L2

 

 

 

 

ØA/L1

 

 

 

 

GND

 

 

 

 

1750 POWER RECORDER

 

 

 

 

VOLTAGE

 

 

 

 

POWER

 

 

 

SD

 

 

 

 

A

B

C

N

 

 

 

 

 

ETHERNET

100-240 V

 

 

 

 

47- 63 Hz

 

 

 

 

ON

 

 

 

 

CURRENT

 

 

LINK

BUSY

 

 

 

C/L3

A/L1

N

GND

B/L2

azd08f.eps

Figure 10. Three-Phase High Leg

Example: A way to get a 120 V single phase feed by tapping across part of a leg in a delta power system

21

Image 29
Contents 1750 Limited Warranty and Limitation of Liability Table of Contents 1750 List of Tables 1750 List of Figures 1750 Introduction Power RecorderContacting Fluke XW Warning Safety InformationSymbols Meaning AccessoriesFluke 1750 Power Recorder FeaturesInput Terminals and Controls Applying the Front Panel Decal Applying the Front Panel DecalConnecting the Supplemental Ground Terminal Installing Power View on the PDA Charging the PDA BatteryInstalling the Software Language Selection PC System Requirement for Power AnalyzeInstalling Power Analyze Work Flow Installing the Power Recorder at a FacilityConnecting the Recorder to the Wiring Installing the RecorderFinishing UP Verifying Your ConnectionManaging Recorded Data Power Type DiagramsExample Branch circuit at an outlet One-Phase IT No Neutral One-Phase Split Phase GND Three-Phase Delta Three-Phase IT Three-Phase High Leg Example a variant of power transformer winding type Element Delta ØC/L3 ØB/L2 Connecting to the Recorder Communicating with the Recorder Using Power ViewPower View Menus Navigating in Power View on the PDAIcons on the Menu Bar Fluke Menu TreeHome Screen Azd113.bmp Downloading Data and Erasing Memory Azd117.bmp Azd108s.bmp Azd109s.bmp Scope Screen Viewing Live DataPhasor Screen Meter ScreenTrend Screen Harmonics ScreenViewing Phases Setting Up the RecorderSetup screen shows setup options Probe Detect Setting the ClockAdding a Measurement Description Setting the IP AddressUsing Phase Swap Configure Nominal Power ValuesAssign Recorder Name and Password Setting the Volts and Current RatioAzd132.bmp Working with Annotations Change Display Language and Phase IdentifierAzd137.bmp Using Image or Voice Annotations Turn off the Recorder Cleaning and MaintenanceRegulatory Information for Wireless Communication Input Specifications General SpecificationsSynchronization and Sampling Voltage and Current MeasurementsVoltage and Current Measurement Accuracy Power and PF MeasurementTransient Voltage Impulse Dip Sag and Swell MeasurementsEnvironmental and Safety Specifications External Interface Specifications