Fluke 1750 specifications Element Delta

Page 31

Power Recorder

Power Type Diagrams

A/L1

ØA/L1

 

 

 

GND

ØB/L2

 

GND

 

 

 

 

 

 

ØC/L3

 

 

 

B/L2

 

 

 

 

C/L3

1750 POWER RECORDER

 

 

 

 

VOLTAGE

 

 

 

 

POWER

 

 

 

SD

 

 

 

 

A

B

C

N

 

 

 

 

 

ETHERNET

100-240 V

 

 

 

 

47-63Hz

 

 

 

 

ON

 

 

 

 

CURRENT

 

 

LINK

BUSY

 

 

 

azd13f.eps

Figure 12. 2-Element Delta

Example: Blondel or Aron connection, used to measure power like a two-element revenue power meter.

23

Image 31
Contents 1750 Limited Warranty and Limitation of Liability Table of Contents 1750 List of Tables 1750 List of Figures 1750 Introduction Power RecorderContacting Fluke XW Warning Safety InformationSymbols Meaning AccessoriesFluke 1750 Power Recorder FeaturesInput Terminals and Controls Applying the Front Panel Decal Applying the Front Panel DecalConnecting the Supplemental Ground Terminal Installing the Software Charging the PDA BatteryInstalling Power View on the PDA Installing Power Analyze PC System Requirement for Power AnalyzeLanguage Selection Work Flow Installing the Power Recorder at a FacilityConnecting the Recorder to the Wiring Installing the RecorderFinishing UP Verifying Your ConnectionManaging Recorded Data Power Type DiagramsExample Branch circuit at an outlet One-Phase IT No Neutral One-Phase Split Phase GND Three-Phase Delta Three-Phase IT Three-Phase High Leg Example a variant of power transformer winding type Element Delta ØC/L3 ØB/L2 Connecting to the Recorder Communicating with the Recorder Using Power ViewPower View Menus Navigating in Power View on the PDAIcons on the Menu Bar Fluke Menu TreeHome Screen Azd113.bmp Downloading Data and Erasing Memory Azd117.bmp Azd108s.bmp Azd109s.bmp Scope Screen Viewing Live DataPhasor Screen Meter ScreenTrend Screen Harmonics ScreenViewing Phases Setting Up the RecorderSetup screen shows setup options Probe Detect Setting the ClockAdding a Measurement Description Setting the IP AddressUsing Phase Swap Configure Nominal Power ValuesAssign Recorder Name and Password Setting the Volts and Current RatioAzd132.bmp Working with Annotations Change Display Language and Phase IdentifierAzd137.bmp Using Image or Voice Annotations Turn off the Recorder Cleaning and MaintenanceRegulatory Information for Wireless Communication Voltage and Current Measurements General SpecificationsInput Specifications Synchronization and SamplingDip Sag and Swell Measurements Power and PF MeasurementVoltage and Current Measurement Accuracy Transient Voltage ImpulseEnvironmental and Safety Specifications External Interface Specifications