Fluke 1750 specifications Regulatory Information for Wireless Communication

Page 57

Power Recorder

Regulatory Information for Wireless Communication

Regulatory Information for Wireless Communication

WCaution

Any changes or modifications to the wireless 2.4 GHz radio not expressly approved by Fluke Corporation could void the user's authority to operate the equipment.

The distance between the Recorder and the human body must be 20 cm (7.9 inches) during wireless communication.

FCC ID: T68FLK1750 or QOQWT 11 (see rear decal on Fluke 1750 for the appropriate ID).

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

Class A digital device: A digital device that is marketed for use in a commercial, industrial or business environment, exclusive of a device which is marketed for use by the general public or is intended to be used in the home.

Class B digital device: A digital device that is marketed for use in a residential environment notwithstanding use in commercial, business and industrial environments. Examples of such devices include, but are not limited to, personal computers, calculators, and similar electronic devices that are marketed for use by the general public.

The Fluke 1750 Power Recorder (wireless host) has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

In addition, the internal limited modular radio has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

The term “IC:” before the radio certification number only signifies that Industry of

Canada technical specifications were met.

49

Image 57
Contents 1750 Limited Warranty and Limitation of Liability Table of Contents 1750 List of Tables 1750 List of Figures 1750 Introduction Power RecorderContacting Fluke XW Warning Safety InformationSymbols Meaning AccessoriesFluke 1750 Power Recorder FeaturesInput Terminals and Controls Applying the Front Panel Decal Applying the Front Panel DecalConnecting the Supplemental Ground Terminal Charging the PDA Battery Installing the SoftwareInstalling Power View on the PDA PC System Requirement for Power Analyze Installing Power AnalyzeLanguage Selection Work Flow Installing the Power Recorder at a FacilityConnecting the Recorder to the Wiring Installing the RecorderFinishing UP Verifying Your ConnectionManaging Recorded Data Power Type DiagramsExample Branch circuit at an outlet One-Phase IT No Neutral One-Phase Split Phase GND Three-Phase Delta Three-Phase IT Three-Phase High Leg Example a variant of power transformer winding type Element Delta ØC/L3 ØB/L2 Connecting to the Recorder Communicating with the Recorder Using Power ViewPower View Menus Navigating in Power View on the PDAIcons on the Menu Bar Fluke Menu TreeHome Screen Azd113.bmp Downloading Data and Erasing Memory Azd117.bmp Azd108s.bmp Azd109s.bmp Scope Screen Viewing Live DataPhasor Screen Meter ScreenTrend Screen Harmonics ScreenViewing Phases Setting Up the RecorderSetup screen shows setup options Probe Detect Setting the ClockAdding a Measurement Description Setting the IP AddressUsing Phase Swap Configure Nominal Power ValuesAssign Recorder Name and Password Setting the Volts and Current RatioAzd132.bmp Working with Annotations Change Display Language and Phase Identifier Azd137.bmp Using Image or Voice Annotations Turn off the Recorder Cleaning and MaintenanceRegulatory Information for Wireless Communication Input Specifications General SpecificationsSynchronization and Sampling Voltage and Current MeasurementsVoltage and Current Measurement Accuracy Power and PF MeasurementTransient Voltage Impulse Dip Sag and Swell MeasurementsEnvironmental and Safety Specifications External Interface Specifications