Fluke 1750 specifications Meter Screen, Phasor Screen

Page 44

1750

Operators Manual

Meter Screen

The Meter screen shows numeric readings for all selected phases.

Azd122.bmp

Phasor Screen

The Phasor screen shows voltage (long arrows with solid arrowheads), current amplitudes, and phase angles. This screen is used to verify proper test lead and current probe connections. You can use the V and A arrows on the upper right of the screen to change the scaling of voltage and current on the PHASOR diagram.

You can easily correct an erroneous Recorder connection by going directly to Menu\1750 Setup\Phase Swap () and using the Recorder to internally invert a CT, swap a voltage or CT phase, or modify a scaling parameter, then return to the screen to verify that the correction has been made. There is no need to touch the cables. See “Phase Swap” later in the manual for additional information.

Azd123.bmp

36

Image 44
Contents 1750 Limited Warranty and Limitation of Liability Table of Contents 1750 List of Tables 1750 List of Figures 1750 Power Recorder IntroductionContacting Fluke Safety Information XW WarningAccessories Symbols MeaningFeatures Fluke 1750 Power RecorderInput Terminals and Controls Applying the Front Panel Decal Applying the Front Panel DecalConnecting the Supplemental Ground Terminal Installing Power View on the PDA Charging the PDA BatteryInstalling the Software Language Selection PC System Requirement for Power AnalyzeInstalling Power Analyze Installing the Power Recorder at a Facility Work FlowInstalling the Recorder Connecting the Recorder to the WiringVerifying Your Connection Finishing UPPower Type Diagrams Managing Recorded DataExample Branch circuit at an outlet One-Phase IT No Neutral One-Phase Split Phase GND Three-Phase Delta Three-Phase IT Three-Phase High Leg Example a variant of power transformer winding type Element Delta ØC/L3 ØB/L2 Communicating with the Recorder Using Power View Connecting to the RecorderNavigating in Power View on the PDA Power View MenusIcons on the Menu Bar Menu Tree FlukeHome Screen Azd113.bmp Downloading Data and Erasing Memory Azd117.bmp Azd108s.bmp Azd109s.bmp Viewing Live Data Scope ScreenMeter Screen Phasor ScreenHarmonics Screen Trend ScreenSetting Up the Recorder Viewing PhasesSetup screen shows setup options Setting the Clock Probe DetectSetting the IP Address Adding a Measurement DescriptionConfigure Nominal Power Values Using Phase SwapSetting the Volts and Current Ratio Assign Recorder Name and PasswordAzd132.bmp Change Display Language and Phase Identifier Working with AnnotationsAzd137.bmp Using Image or Voice Annotations Cleaning and Maintenance Turn off the RecorderRegulatory Information for Wireless Communication General Specifications Input SpecificationsSynchronization and Sampling Voltage and Current MeasurementsPower and PF Measurement Voltage and Current Measurement AccuracyTransient Voltage Impulse Dip Sag and Swell MeasurementsExternal Interface Specifications Environmental and Safety Specifications