Fluke 1750 specifications Example a variant of power transformer winding type

Page 30

1750

Operators Manual

 

 

 

 

A/L1

ØA/L1

 

 

 

 

GND

 

 

 

GND

 

 

 

 

ØC/L3

 

 

 

B/L2

ØB/L2

 

 

 

 

 

 

 

 

C/L3

1750 POWER RECORDER

 

 

 

 

VOLTAGE

 

 

 

 

POWER

 

 

 

SD

 

 

 

 

A

B

C

N

 

 

 

 

 

ETHERNET

100-240 V

 

 

 

 

47-63Hz

 

 

 

 

ON

 

 

 

 

CURRENT

 

 

LINK

BUSY

 

 

 

 

 

 

 

azd18f.eps

Figure 11. Three-Phase Open Leg

Example: A variant of power transformer winding type.

22

Image 30
Contents 1750 Limited Warranty and Limitation of Liability Table of Contents 1750 List of Tables 1750 List of Figures 1750 Power Recorder IntroductionContacting Fluke Safety Information XW WarningAccessories Symbols MeaningFeatures Fluke 1750 Power RecorderInput Terminals and Controls Applying the Front Panel Decal Applying the Front Panel DecalConnecting the Supplemental Ground Terminal Charging the PDA Battery Installing the SoftwareInstalling Power View on the PDA PC System Requirement for Power Analyze Installing Power AnalyzeLanguage Selection Installing the Power Recorder at a Facility Work FlowInstalling the Recorder Connecting the Recorder to the WiringVerifying Your Connection Finishing UPPower Type Diagrams Managing Recorded DataExample Branch circuit at an outlet One-Phase IT No Neutral One-Phase Split Phase GND Three-Phase Delta Three-Phase IT Three-Phase High Leg Example a variant of power transformer winding type Element Delta ØC/L3 ØB/L2 Communicating with the Recorder Using Power View Connecting to the RecorderNavigating in Power View on the PDA Power View MenusIcons on the Menu Bar Menu Tree FlukeHome Screen Azd113.bmp Downloading Data and Erasing Memory Azd117.bmp Azd108s.bmp Azd109s.bmp Viewing Live Data Scope ScreenMeter Screen Phasor ScreenHarmonics Screen Trend ScreenSetting Up the Recorder Viewing PhasesSetup screen shows setup options Setting the Clock Probe DetectSetting the IP Address Adding a Measurement DescriptionConfigure Nominal Power Values Using Phase SwapSetting the Volts and Current Ratio Assign Recorder Name and PasswordAzd132.bmp Change Display Language and Phase Identifier Working with AnnotationsAzd137.bmp Using Image or Voice Annotations Cleaning and Maintenance Turn off the RecorderRegulatory Information for Wireless Communication Synchronization and Sampling General SpecificationsInput Specifications Voltage and Current MeasurementsTransient Voltage Impulse Power and PF MeasurementVoltage and Current Measurement Accuracy Dip Sag and Swell MeasurementsExternal Interface Specifications Environmental and Safety Specifications