SECTION 2: CIRCUIT REQUIREMENTS
110V Operation
Serious personal injury could occur if you connect the machine to power before com- pleting the setup process. DO NOT connect the machine to the power until instructed later in this manual.
Electrocution or fire could result if machine is not grounded and installed in compliance with electrical codes. Compliance MUST be verified by a qualified electrician!
Full Load Amperage Draw
This machine draws the following amps under maximum load:
Amp Draw | 14 Amps |
Power Supply Circuit Requirements
The power supply circuit for your machine MUST be grounded and rated for the amperage given below. Never replace a circuit breaker on an exist- ing circuit with one of higher amperage without consulting a qualified electrician to ensure compli- ance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, con- sult a qualified electrician.
Minimum Circuit Size | 20 Amps |
Power Connection Device
The Model G0462 comes prewired with a NEMA
GROUNDED |
Grounding Prong |
Neutral Hot |
Figure 2. NEMA 5-15 plug and receptacle.
Extension Cords
Using extension cords may reduce the life of the motor. Instead, place the machine near a power source. If you must use an extension cord:
•Use at least a 14 gauge cord that does not exceed 50 feet in length!
•The extension cord must also have a ground wire and plug pin.
•A qualified electrician MUST size cords over 50 feet long to prevent motor damage.
G0462 Wood Lathe (Mfg. Since 3/10) |