Honeywell XYR 5000 LINE manual Square Root Function, Transmitter Device Status Registers

Page 40

6.5.4 Transmitter Device Status Registers

The following are the values for the Device Status holding registers. These registers are bit field registers represented as a 32-bit floating point values for Transmitters.

Value

Transmitter Device Status

1

Transmitter Online

2

Low Battery Condition

► 4

Alarm Condition (WN571 only)

8

Sensor Error Condition

16

Sensor Overrange Condition

32

System Error Condition

64

Switch Input 1 Closed

128

Switch Input 2 Closed

► 256

Sq. Root Funct. (Diff. Pressure only - see

 

below)

Again, like Section 6.4.3, the status can be resolved by subtracting the largest number listed above from the value received from the holding register, and then subtracting the next highest and so on until the result is 0. Each of the values used indicate the respective condition listed above.

For example, the holding register reads 9, then subtract 8 and get 1. Then subtract 1 from 1 and get 0. Thus from the list above, we have a Sensor Error Condition and the Transmitter is online.

6.6Square Root Function

The Square Root Function only works with the Differential Pressure Transmitter. When the DP Transmitter is in Orifice mode, a Square Root calculation is performed. You have the option to display the Square Root Calculation. If this option is enabled, it will be displayed as Percent Square Root in WMT and sent to a Modbus Register.

The Square Root Calculation must be enabled through WMT. To display the Square Root Calculation, first open the Configuration dialog box for the DP Transmitter and select the Operation Mode tab. Make sure you have selected Orifice Flow from the mode menu. Then, from the Flow Units drop-down list, select Percent - Vol Flow. If the Density check box is selected, then Percent - Mass Flow can also be selected from the Flow Units drop-down list to show the Square Root Calculation.

33

Image 40
Contents Base Radio User Guide XYR 5000 Line 34-XY-25-05 Rev 08/06Page Base Radio FCC CertificationContacts Revision NotesTelephone Table of Contents Quare R OOT F Unction Overall Wiring Schematic Table of FiguresIntroduction Using this ManualAbout the Device Unpacking Software CompatibilityOverall Wiring Schematic Quick StartPage Mechanical Installation InstallationBase Radio Positioning General Layout Electrical Installation Electrical SpecificationsTerminal Block Labels Wiring Power to the Base Radio Wiring RS-485 to the Base RadioWiring the RS-485/232 Converter to the Base Radio Wiring RS-485 to the Base RadioWiring the RS-485/USB Converter to the Base Radio USB Driver InstallationDaisy-Chaining Multiple Base Radios to Single RS-485/Power Wiring the DB-9 RS-485 Cable to the Base RadioUSB Converter’s Male DB-9 Connector USB Driver Un-installationDaisy-Chaining Power to Multiple Base Radios Daisy-Chaining RS-485 to Multiple Base RadiosTerminating Communications Wiring to the Base Radio Daisy-Chaining RS-485 to Multiple Base RadiosGrounding the Base Radio High Gain AntennaBase Radio Displayed Messages General ConfigurationRead Only Sequence Overall Configuration Menu Map Read Only SequenceSetting the User Password Menu Map to Password SettingConfiguring the RF Communications RF Channel SelectionMenu Map to RF Baud Rate Setting RF Baud Rate SelectionHigh RF ID Setting High Rfid SettingBase Radio Setup Modbus Baud Rate SettingModbus Device ID Setting Menu Map to Modbus Baud Rate SettingPage Modbus Parity Setting Modbus Mapping Mode SettingModbus Communication Protocol RegmodeCommand 03-Read Holding Registers Modbus CommandsCommand 08- Diagnostic Command 12- Get Com Event Log Command 11- Get Com Event CounterCommand 17- Report Slave ID Command 43- Read Device ID Base Radio Holding RegistersRegister Address Description Register Type Register Address Description Base Radio Device Type Registers Base Radio Device Status Registers Base Radio On/Offline Transmitter Registers Value Base Radio Device StatusDevice ID Mapping Mode Register Mapping ModeTransmitter Holding Registers Register AddressTransmitter Device Type Holding Registers Value Device TypeAlarm Condition WN571 only Square Root FunctionTransmitter Device Status Registers Value Transmitter Device StatusTechnical Specifications Overall Base Radio Dimensions Appendix a Navigating the Menus Appendix B Base Radio Menu Map Figure A- 1 Base Radio Menu MapAppendix C Modbus Register Definitions Page Page Page Honeywell