Wire for remote (RC-10) operation as follows (see Figure 21):

1.Install a jumper wire between terminals #6 and terminal #2 (see Figure 22).

2.Connect the white wire of the RC-10 controller unit to terminal #1 (see Figure 23).

3.Connect the red wire of the RC-10 controller unit to terminal #2.

4.Connect the black wire of the RC-10 controller unit to terminal #5.

5.Connect the power source to the lift.

NOTE: If the unit does not activate, check to make sure the 9 volt battery is working and make sure the dip switches in the send- ing unit match the dip switch settings in the controller unit (see Figure 24).

Figure 22. Contacts Connection

Red lead

Black lead

Figure 23. Contacts Connection

Figure 24. Dip Switches

15

Image 16
Contents Plasma Display Electric Pop-Up Lift PUL Before YOU BeginTools Required for Installation WEIGHT, SIZE, and Vertical Travel SpecificationsContents Weight, Size, and Vertical Travel Model Dimensional Drawing Front ViewInspect The Unit Inspect and Test the Unit Before InstallingTest The Unit Prepare the FURNITURE/CABINET and Install the Lift General GuidelinesPrepare the Furniture/Cabinet Furniture Opening Finish Piece OptionsRetracted Position Finish Piece Option Retracted Position Finish Piece Furniture Install the PUL into the Cabinet Secure LiftAttach Brackets to the Display Install the Display on the LiftMount the Display Width Adjustment AdjustmentsAdjust Vertical Travel This page Intentionally Blank Wiring Examples PushbuttonThis page Intentionally Blank Remote RC-10 Red lead Black leadThis page Intentionally Blank Two Dry Contact Closures Volt Out SupplyLow Voltage Sensing This page Intentionally Blank Troubleshooting Possible Symptoms Causes Suggested ActionDescription Wiring Options Wiring the RC-10