Chief Manufacturing 8805-000009 Volt Out Supply, Two Dry Contact Closures, Low Voltage Sensing

Page 18

Instruction Manual

Plasma Display Electric Pop-Up Lift

 

 

12 Volt Out Supply

This internal power supply can be used to power external devices &/or to initiate specific functions (see Pushbutton operation and Figure 25).

1.Connect one lead to 12 VOLT GROUND (terminal #9).

2.Connect one lead to 12 VOLTS OUT (terminal #10).

24 Volt Out Supply

This internal power supply can be used to power external devices & remote controllers (see Figure 26).

1.Connect one lead to 24 VOLT COMMON (terminal #2).

2.Connect one lead to 24 VOLTS OUT (terminal #1).

Two Dry Contact Closures

NOTE: Dry contacts are rated for 1 Amp @ 24 volts.

These contacts can be used to complete circuits to external devices (see Figure 27 and Figure 28).

1.Connect one lead to terminal #17 (extend limit common).

2.Connect one lead to terminal #16 (closes when unit reaches full extension).

3.Connect one lead to terminal #19 (retract limit common).

4.Connect one lead to terminal #18 (closes when unit is fully retracted).

Low Voltage Sensing

1. Connect positive lead (5 - 30 volts AC/DC) to terminal #7 and ground of switching device to terminal #8 (see Figure 29). Unit extends when voltage is sensed, retracts when voltage ceases.

Example using internal 12 volt DC supply (Figure 30): 1 2 3 4 5 6 7 8

Figure 30. 12 Volt DC Supply

Figure 25. 12 Volts

Figure 24. 26 Volts

Figure 27. Extend Dry Contacts

Figure 28. Retract Dry Contacts

Figure 29. Low Voltage Sensing

17

Image 18
Contents Plasma Display Electric Pop-Up Lift PUL Before YOU BeginTools Required for Installation WEIGHT, SIZE, and Vertical Travel SpecificationsContents Weight, Size, and Vertical Travel Model Dimensional Drawing Front ViewInspect and Test the Unit Before Installing Inspect The UnitTest The Unit Prepare the Furniture/Cabinet Prepare the FURNITURE/CABINET and Install the LiftGeneral Guidelines Furniture Opening Finish Piece OptionsRetracted Position Finish Piece Option Retracted Position Finish Piece Furniture Install the PUL into the Cabinet Secure LiftInstall the Display on the Lift Attach Brackets to the DisplayMount the Display Adjustments Width AdjustmentAdjust Vertical Travel This page Intentionally Blank Wiring Examples PushbuttonThis page Intentionally Blank Remote RC-10 Red lead Black leadThis page Intentionally Blank Volt Out Supply Two Dry Contact ClosuresLow Voltage Sensing This page Intentionally Blank Troubleshooting Possible Symptoms Causes Suggested ActionDescription Wiring Options Wiring the RC-10