Chief Manufacturing 8805-000009 Inspect and Test the Unit Before Installing, Inspect The Unit

Page 6

Instruction Manual

Plasma Display Electric Pop-Up Lift

 

 

INSPECT AND TEST THE UNIT BEFORE INSTALLING

Inspect The Unit

1.Carefully inspect the Plasma Display Electric Pop-Up Lift (PUL) for shipping damage. If any damage is apparent, call your carrier claims agent and do not continue with the installa- tion until the carrier has reviewed the damage.

NOTE: Read all assembly instructions before starting assem- bly.

2.Carefully inspect PUL components for damage, checking verti- cal extrusion arms to make sure they are parallel.

IMPORTANT: Before mounting the lift in the furniture/cabinet, make the following tests to be sure that it operates properly and has not been damaged in shipping.

Test The Unit

1.Set the PUL on a clean, level surface.

2.Connect the motor control box to the control circuit housing (see Figure 1, Figure 2, and Figure 3).

3.Install two terminal blocks in control box (see Figure 2).

NOTE: The lift is supplied with a momentary push button on the end of a cable to help you pretest the operation.

3.Connect the momentary push button (provided) cable leads to terminals #6 and #1 and add a jumper wire (provided - electri- cal wire about 4 in. long with 1/4 in. stripped at each end) between terminals #2 and #5 on the same terminal block (see Fig. 4).

4.Plug the lift’s power cord (see Figure 3) into a 110V 60 Hz or 220V 50 Hz (as appropriate) 15-amp outlet.

NOTE: The lift draws approximately 1.5 amps.

WARNNG: Be aware during the installation that this is a motorized device, and there are pinch points for people and for electrical wiring. Keep hands and electrical wiring away from internal components of the mechanism

5.Operate the lift much like a garage-door opener: press the but- ton when the lift is at its “bottom” position and it will move “up”; press again when it is at its “top” position and it will move “down”; press while moving and it will stop.

Use the push button to check that the lift runs to the top and bottom of its travel without any interference that might indicate damage during shipment.

6.Unplug the lift’s power cord.

Figure 1. Connection to Housing

Figure 2. Front Connection to Control Box

Figure 3. Back Connection and Power Cord to Control Box

To

To push button

To jumper

Figure 4. Test Wiring

5

Image 6
Contents Plasma Display Electric Pop-Up Lift PUL Before YOU BeginTools Required for Installation WEIGHT, SIZE, and Vertical Travel SpecificationsContents Weight, Size, and Vertical Travel Model Dimensional Drawing Front ViewInspect and Test the Unit Before Installing Inspect The UnitTest The Unit Prepare the Furniture/Cabinet Prepare the FURNITURE/CABINET and Install the LiftGeneral Guidelines Furniture Opening Finish Piece OptionsRetracted Position Finish Piece Option Retracted Position Finish Piece Furniture Install the PUL into the Cabinet Secure LiftInstall the Display on the Lift Attach Brackets to the DisplayMount the Display Adjustments Width AdjustmentAdjust Vertical Travel This page Intentionally Blank Wiring Examples PushbuttonThis page Intentionally Blank Remote RC-10 Red lead Black leadThis page Intentionally Blank Volt Out Supply Two Dry Contact ClosuresLow Voltage Sensing This page Intentionally Blank Troubleshooting Possible Symptoms Causes Suggested ActionDescription Wiring Options Wiring the RC-10