Instruction Manual | Plasma Display Electric |
|
|
WIRING EXAMPLES
The information on the following pages cover the most common wiring options:
•Pushbutton
•Extend and Retract Terminals to be Triggered By Separate Dry Contacts
•Remote
•12 Volt out supply
•24 Volt out supply
• | Two dry contact closures | Figure 16. 12 Volt Supply Jumper |
| ||
• | Voltage Sensing |
|
Pushbutton
Wire for pushbutton operation as follows:
1.Install a wire between terminal 5 (extend/retract common) and ground terminal 3 (see Figure 16).
2.Connect one wire from pushbutton to terminal #4
(12 VDC power supply) and the other wire from the pushbut- | Figure 17. Pushbutton Wires |
ton to terminal #6 (extend/retract) (see Figure 17). |
|
With the unit plugged in, push the button once and the unit should |
|
extend. Push the button during travel and the unit will stop at that |
|
location. Push the button after the unit is extended or stopped in |
|
| |
Extend and Retract Terminals to be Triggered By | Common |
Separate Dry Contacts |
|
These terminals can be used with a wall switch or a separate set of
dry contacts for dedicated extend and dedicated retract. Momentary Figure 18. Common for Extend and Retract Contacts contacts are preferable.
NOTE: The connection between the ground (#13) and any other | Service Extend | |
| ||
terminal connection must be broken (open) before completing the |
| |
next circuit. | Extend | |
1. Connect the common to terminal #13 (see Figure 18). | ||
| ||
2. Connect the extend to terminal #11 (see Figure 19). |
| |
3. Connect the retract to terminal #12 (see Figure 20). | Figure 19. Extend Contact Wiring | |
Completing the circuit between terminal #13 and terminal #11 will |
| |
cause the unit to extend to the show position (see “Adjust Vertical |
| |
Travel” on page 11 to change height setting). Completing the cir- |
| |
cuit between terminal #13 and terminal #12 will cause the unit to |
| |
retract to the closed position. |
| |
| Retract | |
| Figure 20. Retract Contact Wiring |
13