TOA Electronics C-RM1000 CU Expanded Digital video recorder system Cascade-connection

Page 54

13.2.2. Expanded Digital video recorder system (Cascade-connection)

 

 

 

 

 

REMOTE

 

 

Interface Unit C-RF1000

CONTROLLER

 

 

 

INPUT-B

 

 

 

 

 

 

 

 

 

REMOTE CONTROLLER

 

 

 

 

 

 

1 2 3 4

POWER/DVR

 

 

 

 

 

 

INTERFACE UNIT C-RF1000

 

 

 

 

DVR CONTROL

 

 

 

 

 

OUTPUT-A

 

 

 

 

 

 

 

Supplied modular cable (3 m (9.8 ft))

 

 

 

 

 

 

Group 1

 

 

 

 

 

 

 

 

Digital Video Recorder 1

 

 

 

 

 

 

 

 

 

 

C-DR091 or

RM IN-A

 

 

 

 

Termination: OFF

Monitor

Combination Camera

C-DR161 Series

 

 

 

output 1

 

 

 

 

 

 

Group 1

Remote REMOTE

Controller 1 CONTROLLER

C-RM1000 OUTPUT-B

*1 RS-485

RM

1-16OUT-B

To AC Main

RS-485

Digital Video Recorder 2

LINK

Monitor output 2

To LAN

Monitor output 1

RM IN-B Termination: OFF

Master monitor

DVR 1 Live display only

AC adapter

Remote

Controller 2

*1

 

 

 

 

Monitor

RS-485

 

 

 

 

 

 

 

output 2

1-16

 

 

RM

 

 

 

 

 

 

OUT-B

 

 

 

 

 

 

 

DVR 2 Live display only

RS-485

To LAN

 

Group 2

*1

Digital Video Recorder 3

RS-485

RM IN-B

Monitor

Remote

 

Termination: OFF

 

Controller 3

 

 

 

output 1

Group 2

 

 

 

 

Master

 

 

 

 

 

monitor

 

 

 

 

 

 

 

1-16

RM

OUT-B

 

LINK

 

 

Monitor

 

 

 

output 2

 

 

 

 

DVR 3

 

 

 

 

 

 

Live display

To LAN

 

 

only

Digital Video Recorder 8

*1

RS-485

1-16

RM IN-B

Monitor

 

 

 

 

 

 

output 1

Remote

 

Termination: ON

 

 

 

Controller 4

 

 

 

 

 

 

 

 

DVR 8

 

 

 

 

Live display

 

 

 

 

 

Monitor

only

 

 

 

output 2

 

 

 

 

 

 

To LAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Coaxial cable (video signal)

 

 

PC

 

 

 

: CPEV-S 0.65-2C (RS-485 control line)

 

 

 

: Modular cable, 3 m (9.8 ft).

 

 

 

(supplied with the C-RM1000)

LAN

 

 

 

 

 

*1 Match the Combination Camera’s address to the Digital Video Recorder’ s video input number.

54

Image 54
Contents Remote Controller Operating InstructionsTable of Contents SettingsGeneral Description Operation Digital Video Recorder OperationWhen YOU Need Help ConnectionsWhen Installing the Unit Safety PrecautionsSafety Symbol and Message Conventions When the Unit is in UseModifications Functions Connectable Equipment and Their Maximum Numbers Handling PrecautionsEquipment that can be controlled by the Remote Controller DR091 and C-DR161 Series Digital Video RecordersDefinition Digital Video Recorder number DVR Multi-segment split screen displayNomenclature and Functions Menu display mode Joystick Live modePlayback mode Focus Key Focus Live modeBottom Surface Indications AC Adapter Power Input Terminal DC in 13.8Rear Panel DVR Control Output Terminal B screwless typeMonitor Selection Equipment SelectionDigital Video Recorder Selection Group Selection cascade connection onlyCamera Selection Full screen and the Full key lights. The camera Full Screen DisplayPress the Full key Designated cameras image is displayed on Number is displayed on the LCD screenMulti-Screen Display Segment Split-Screen DisplaySegment Split Screen Display Changing the Multi-Screen Display Position Sequential DisplayGroup Sequential Display Zoom Display Electronic zoom Camera Rotation and Zoom Operation Using the Joystick Focus AdjustmentCombination Camera Operation Iris Operation Communication method Type B only Auto-Function OperationCamera Position Selection Focus Speed Settings Utilization of the Abbreviation Number FunctionCombination Camera Menu Display Storing the Preset Positions ExampleLED indication during recording Digital Video Recorder OperationVideo Recording Priority recording operationPlayback Operation Resetting alarm event recordingPlayback mode settings Making normal recordingTime skip forward/reverse playback Stop operationForward/reverse quick playback Pause operationEarliest image playback Instant event access playbackFrame advance/reverse playback Latest image revers playbackSearch Operation Digital Video Recorder Menu DisplayMotion Detection Area Settings ArchivingTriplex Settings Entering the Digital Video Recorder Password Log-inLog-out Other Operations Log-In and Log-OutAlarm Operations When alarm is triggeredAbbreviation Number To reset alarm Putting screen switching on hold when an alarm occursTo stop a buzzer tone Setting Item Summaries PasswordRemote controller menu list YES TOA-A TOA-B Bosch PELCO-DSetting Keys and Display Screen Keys to be used for settingsLCD screen display Operation during menu display Basic Setting OperationsDisplaying the menu Closing the menuSetting contents Function SettingsGroup settings When selecting Setting …When selecting Transfer… When selecting Erase…Abbreviation Setting contents Abbreviation Quick display function When the cameras protocol is TOA-A Type a Abbreviation Function programmingWhen the cameras protocol is TOA-B Type B Default abbreviation number settingsCamera Protocol TOA-AOperation Level Passwords and operation levels PatternPassword Settings Focus speedBuzzer tone Key operation tone 12.4.10. I/O SpeedDVR check N I T O R L O C K Initial status Joystick position adjustmentLanguage ExpansionDigital video recorder Equipment ConnectionsCombination camera Interface unitSystem Example Basic systemExpanded Digital video recorder system Cascade-connection Interface Unit C-RF1000Remote Controller connections using the dedicated cable Remote Controller Indication and Status Digital Video Recorder Failure IndicationStopping the buzzer tone Troubleshooting Operation Guide Equipment selectionOther operations Specifications AccessoriesOptional products