TOA Electronics C-RM1000 CU operating instructions Specifications, Accessories, Optional products

Page 60

17. SPECIFICATIONS

Power Source

12 V AC, 60 Hz (use of the supplied AC adapter)

 

or 12 V DC (supplied from the digital video recorder)

Current Consumption

80 mA (use of the supplied AC adapter)

 

 

Digital Video Recorder

RS-485, RJ11 (6P 6C)

Control

(when the included 3-meters (9.8 ft) modular cable is used)

 

RS-485, screwless connector (3 pins)

 

(with cable length of 3-meters (9.8 ft) and more, or when C-RF1000 (option) is used)

 

 

Alarm Signal

Continuous alarm tone (can be turned on and off through the menu)

 

 

Maximum Cable Distance

1.2 km (3,937 ft) *

Function

Password setting, DVR Group setting, Abbreviation function (512 types),

 

Preset position setting, Language choice (English/French)

 

 

Operating Temperature

0°C to +40°C (32°F to 104°F)

Operating Humidity

Under 80%RH (no condensation)

 

 

Finish

Panel: Surface-treated steel plate, silver, paint

 

Sides: Rubber

 

 

Dimensions

323.6 (W) x 112.7 (H) x 181 (D) mm (12.7 (W) x 4.4 (H) x 7.1 (D) inch)

Weight

1.6 kg (3.5 lb) (excluding AC adapter)

 

 

*Applies to the system where the unit and digital video recorder are connected in a matched pair. Represents the total of connected cable distances if multiple digital video recorders or Interface units are connected in the system.

Note: The design and specifications are subject to change without notice for improvement.

• Accessories

 

 

AC adapter (1.8 m (5.9 ft))

1

Modular cable (3 m (9.8 ft))

1

• Optional products

 

 

Digital video recorder:

C-DR091/C-DR161 Series

Interface unit:

C-RF1000

 

133-12-992-40

Image 60
Contents Remote Controller Operating InstructionsTable of Contents SettingsGeneral Description Operation Digital Video Recorder OperationWhen YOU Need Help ConnectionsSafety Precautions Safety Symbol and Message ConventionsWhen Installing the Unit When the Unit is in UseModifications Functions Handling Precautions Equipment that can be controlled by the Remote ControllerConnectable Equipment and Their Maximum Numbers DR091 and C-DR161 Series Digital Video RecordersDefinition Digital Video Recorder number DVR Multi-segment split screen displayNomenclature and Functions Joystick Live mode Playback modeMenu display mode Focus Key Focus Live modeAC Adapter Power Input Terminal DC in 13.8 Rear PanelBottom Surface Indications DVR Control Output Terminal B screwless typeEquipment Selection Digital Video Recorder SelectionMonitor Selection Group Selection cascade connection onlyCamera Selection Full Screen Display Press the Full key Designated cameras image is displayed onFull screen and the Full key lights. The camera Number is displayed on the LCD screenMulti-Screen Display Segment Split-Screen DisplaySegment Split Screen Display Changing the Multi-Screen Display Position Sequential DisplayGroup Sequential Display Zoom Display Electronic zoom Camera Rotation and Zoom Operation Using the Joystick Focus AdjustmentCombination Camera Operation Iris Operation Communication method Type B only Auto-Function OperationCamera Position Selection Focus Speed Settings Utilization of the Abbreviation Number FunctionCombination Camera Menu Display Storing the Preset Positions ExampleDigital Video Recorder Operation Video RecordingLED indication during recording Priority recording operationResetting alarm event recording Playback mode settingsPlayback Operation Making normal recordingStop operation Forward/reverse quick playbackTime skip forward/reverse playback Pause operationInstant event access playback Frame advance/reverse playbackEarliest image playback Latest image revers playbackSearch Operation Digital Video Recorder Menu DisplayMotion Detection Area Settings ArchivingTriplex Settings Entering the Digital Video Recorder Password Log-inLog-out Other Operations Log-In and Log-OutAlarm Operations When alarm is triggeredAbbreviation Number To reset alarm Putting screen switching on hold when an alarm occursTo stop a buzzer tone Setting Item Summaries PasswordRemote controller menu list YES TOA-A TOA-B Bosch PELCO-DSetting Keys and Display Screen Keys to be used for settingsLCD screen display Basic Setting Operations Displaying the menuOperation during menu display Closing the menuFunction Settings Group settingsSetting contents When selecting Setting …When selecting Transfer… When selecting Erase…Abbreviation Setting contents Abbreviation Quick display function When the cameras protocol is TOA-A Type a Abbreviation Function programmingWhen the cameras protocol is TOA-B Type B Default abbreviation number settingsCamera Protocol TOA-AOperation Level Passwords and operation levels PatternPassword Settings Focus speedBuzzer tone Key operation tone 12.4.10. I/O SpeedDVR check N I T O R L O C K Joystick position adjustment LanguageInitial status ExpansionEquipment Connections Combination cameraDigital video recorder Interface unitSystem Example Basic systemExpanded Digital video recorder system Cascade-connection Interface Unit C-RF1000Remote Controller connections using the dedicated cable Remote Controller Indication and Status Digital Video Recorder Failure IndicationStopping the buzzer tone Troubleshooting Operation Guide Equipment selectionOther operations Specifications AccessoriesOptional products