Chapter 5: Advanced Serverboard Setup
HDD LED
The HDD LED (for IDE and SATA drives) connection is located on pins 13 and 14 of JF1. Attach the drive LED cable to these pins to display disk activity. See the table on the right for pin defi nitions.
NIC1/2 LEDs
The NIC (Network Interface Control- ler) LED connections for JLAN1 are located on pins 11 and 12 of JF1 and the NIC LED connections for JLAN2 are located on pins 9 and 10 of JF1. Attach the NIC cables to display net- work activity. Refer to the table on the right for pin defi nitions.
Overheat/Fan Fail LED
Connect an LED to the OH/Fan Fail connection on pins 7 and 8 of JF1 to provide warning of system overheat- ing or system fan failure. The LED will fl ash/stay on as long as the fan fail/overheat condition exists. Refer to the table on the right for pin defi nitions and Chapter 3 for details.
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Re- fer to the table on the right for pin defi nitions.
HDD LED
Pin Definitions (JF1)
Pin# Defi nition
13Vcc
14HD Active
NIC1/2 LED
Pin Definitions (JF1)
Pin# | Defi nition |
9/11 | Vcc |
|
|
10/12 Ground
OH/Fan Fail LED
Pin Definitions (JF1)
Pin# Defi nition
7Vcc
8Ground
Power Fail LED
Pin Definitions (JF1)
Pin# Defi nition
5Vcc
6Ground