SUPER MICRO Computer 6014L-M manual Checkpoint

Page 96

SUPERSERVER 6014L-M User's Manual

Checkpoint

86h

87h

88h

89h

8Ch

8Dh

8Fh

91h

95h

96h

97h

98h

99h

9Ah

9Bh

9Ch

9Dh

9Eh

A2h

A3h

A4h

A5h

A7h

A8h

Code Description

The password was checked. Performing any required programming before WIN- BIOS Setup next.

The programming before WINBIOS Setup has completed. Uncompressing the WINBIOS Setup code and executing the AMIBIOS Setup or WINBIOS Setup utility next.

Returned from WINBIOS Setup and cleared the screen. Performing any necessary programming after WINBIOS Setup next.

The programming after WINBIOS Setup has completed. Displaying the power on screen message next.

Programming the WINBIOS Setup options next.

The WINBIOS Setup options are programmed. Resetting the hard disk controller next.

The hard disk controller has been reset. Confi guring the fl oppy drive controller next.

The fl oppy drive controller has been confi gured. Confi guring the hard disk drive controller next.

Initializing the bus option ROMs from C800 next. See the last page of this chapter for additional information.

Initializing before passing control to the adaptor ROM at C800.

Initialization before the C800 adaptor ROM gains control has completed. The adap- tor ROM check is next.

The adaptor ROM had control and has now returned control to BIOS POST. Perform- ing any required processing after the option ROM returned control.

Any initialization required after the option ROM test has completed. Confi guring the timer data area and printer base address next.

Set the timer and printer base addresses. Setting the RS-232 base address next.

Returned after setting the RS-232 base address. Performing any required initializa- tion before the Coprocessor test next.

Required initialization before the Coprocessor test is over. Initializing the Coproces- sor next.

Coprocessor initialized. Performing any required initialization after the Coproces- sor test next.

Initialization after the Coprocessor test is complete. Checking the extended keyboard, keyboard ID, and Num Lock key next. Issuing the keyboard ID command next.

Displaying any soft errors next.

The soft error display has completed. Setting the keyboard typematic rate next.

The keyboard typematic rate is set. Programming the memory wait states next.

Memory wait state programming is over. Clearing the screen and enabling parity and the NMI next.

NMI and parity enabled. Performing any initialization required before passing control to the adaptor ROM at E000 next.

Initialization before passing control to the adaptor ROM at E000h completed. Passing control to the adaptor ROM at E000h next.

B-6

Image 96
Contents Super Manual Revision Release Date February 23 Preface About This ManualManual Organization System Safety Advanced Serverboard SetupAdvanced Chassis Setup BiosPreface Table of Contents System Safety Advanced Serverboard SetupAdvanced Chassis Setup Bios AppendicesPage Chapter Introduction OverviewServerboard Features Processors MemorySerial ATA PCI Expansion SlotsOther Features Onboard Controllers/PortsIntel E7520 Chipset System Block Diagram Server Chassis Features Contacting Supermicro HeadquartersEurope Asia-PacificChapter Server Installation Preparing for SetupUnpacking the System Choosing a Setup Location Rack PrecautionsServer Precautions Rack Mounting Considerations Installing the System into a Rack Basic Installation ProcedureRack hardware optional Installing with Rackmount Kit Installing the Chassis RailsInstalling the Rack Rails Installing the Server into the RackInstalling the Server into a Telco Rack Installing the Server into a Rack Optional Rackmount KitChecking the Serverboard Setup Accessing the inside of the server FigureCheck the system memory Installing add-on cards Check all cable connections and airflowChecking the Drive Bay Setup Page Chapter System Interface Control Panel ButtonsControl Panel LEDs Page Page Chapter System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Installing the Onboard BatteryChapter Advanced Serverboard Setup PrecautionsHandling the Serverboard UnpackingServerboard Installation Installing the Heatsink BracketsInstalling the Serverboard Processor and Heatsink Installation Installing the ProcessorsInstalling the Heatsinks Installed processorInstalled heatsink Removing the Heatsink Connecting Cables Connecting Data CablesConnecting Power Cables Connecting the Control Panel I/O PortsInstalling Memory Dimm Installation See FigureMemory Support PCI card installation Adding PCI CardsPCI slots Serverboard Details Super X6DLP-EG2 LayoutJumper Description Default Setting Connector DescriptionOnboard Indicators Description X6DLP-EG2 Quick ReferenceConnector Definitions ATX Power ConnectorProcessor Power Connector Power LEDPower Fail LED NIC1/2 LEDsOverheat/Fan Fail LED Reset Button Power ButtonJLAN1/2 Ethernet Ports Chassis IntrusionUniversal Serial Bus USB0/1 Universal Serial Bus HeadersFan Headers Speaker/Power LED/Keylock Wake-On-RingWake-On-LAN Connector Power FaultSMB Power I2 C ATX PS/2 Keyboard and PS/2 Mouse PortsJumper Settings JLAN1/2 Enable/DisableExplanation Jumpers Cmos ClearVGA Enable/Disable Power Force OnSMBus to PCI Slots Watch DogOnboard Indicators Alarm ResetJlan LEDs System Status LEDOnboard LED Indicators DS1, DS5 Onboard LED Indicators DS7, DS8Parallel Port, Floppy, IDE and Sata Drive Connections Parallel Printer Port HeaderFloppy Connector Sata ConnectorsIDE Connectors IDE Drive Connectors Pin Definitions IDE1, IDE2Chapter Advanced Chassis Setup PrecautionsStatic-Sensitive Devices Tools RequiredControl Panel System FansInstalling a new fan System Fan FailureReplacing System Cooling Fans Removing a fanDrive Bay Installation/Removal Accessing the Drive BaysSerial ATA Drive Installation CD-ROM Drive Installation Power Supply Power Supply FailureReplacing the Power Supply Accessing the inside of the systemRemoving the power supply Installing a new power supplyPage How To Change the Configuration Data ChapterIntroduction Main Setup ProcessorsSystem Memory Advanced Settings Configure Advanced CPU SettingsCPU Configuration Sub-Menu System Time/System DateCombined Mode Operation IDE Configuration Sub-MenuIDE Configuration ATA Ports DefinitionLBA/Large Mode TypeBlock Multi-Sector Transfer A.R.T. For Hard disk drivesFloppy Configuration PCI/PnP ConfigurationAllocate IRQ to PCI VGA Palette SnoopingPCI IDE BusMaster Offboard PCI/ISA IDE CardSuper IO Configuration Sub-Menu Advanced Chipset Settings Power Configuration Apci ConfigurationWatch Dog Timer PCI/PCI Error LoggingPCI/PCI Express Error Logging Event Log ConfigurationRemote Access Configuration MPS ConfigurationPCI Express Configuration Remote Access Serial Port ModeRedirection After Bios Post Sredir Memory Display DelayUSB Configuration System Health MonitorBoot Settings System Fan MonitorFan Speed Control Modes Fan1 Speed to Fan6 SpeedsBios Settings Configuration Boot Device Priority Hard Disk DrivesRemovable Drives CD/DVD DrivesSecurity Settings Change Supervisor PasswordChange User Password Clear User PasswordLoad Optimal Defaults Exit OptionsSaving Changes and Exit Discarding Changes and ExitLoad Fail-Safe Defaults Appendix a Bios Error Beep Codes Amibios Error Beep CodesBeep Code Error Message Description LED Indicators DS7/DS8 LED Post CodesAppendix B Bios Post Checkpoint Codes Uncompressed Initialization CodesBootblock Recovery Codes Uncompressed Initialization Codes Checkpoint Appendix B Bios Post Checkpoint Codes Checkpoint A9h Aah Abh B0h B1h 00h Page Appendix C Software Installation Serial ATA SataIntel 6300ESB I/O Controller Hub Configuring Sata RAID Adaptec Sata HostRAID Controller DriverAdaptec RAID Configuration Utility ARC Using the Array Configuration Utility ACU Managing Arrays Viewing Array PropertiesDeleting Arrays Creating ArraysPage Assigning Array Properties RAID Levels Adding a Bootable Array Deleting a Bootable Array Initializing Disk DrivesTo initialize drives Page Page Rebuilding Arrays To rebuild an arrayUsing the Disk Utilities To access the disk utilitiesExiting the Adaptec RAID Configuration Utility You can choose from the following optionsInstalling the ICH5R/6300 ESBDriver Installing Other Software Programs and Drivers Installing Additional DriversSupero Doctor Supero Doctor III Interface Display Screen-II Remote Control Page Appendix D System Specifications Weight Power SupplySystem Cooling System Input Requirements