SUPER MICRO Computer 6014L-M manual Chapter, Introduction, How To Change the Configuration Data

Page 69

Chapter 7: BIOS

Chapter 7

AMIBIOS

7-1 Introduction

This chapter describes the AMIBIOS Setup Utility for the X6DLP-EG2. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily upgraded using a fl oppy disk-based program. This chapter describes the basic navigation of the AMIBIOS Setup Utility setup screens.

Starting the BIOS Setup Utility

To enter the AMIBIOS Setup Utility screens, hit the <Delete> key while the system is booting up.

Each main BIOS menu option is described in this user’s guide. The Main BIOS setup menu screen has two main frames. The left frame displays all the options that can be confi gured. “Grayed-out” options cannot be confi gured while options in blue can be confi gured by the user. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: AMI BIOS has default text messages built-in. Supermicro retains the option to include, omit, or change any of these text messages.)

The AMIBIOS Setup Utility uses a key-based navigation system (hot keys). Most of these hot keys can be used at any time during the setup navigation process. These keys include <F1>, <F10>, <Enter>, <ESC>, arrow keys, and Esc. Options printed in Bold are the default settings.

How To Change the Configuration Data

The confi guration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing <Del> at the appropriate time during system boot.

Normally, the only visible POST (Power On Self Test) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens. An AMIBIOS identifi cation string is displayed at the left bottom corner of the screen, below the copyright message.

Warning!! To prevent a possible boot failure, do not shut down or reset the system while updating BIOS..

7-1

Image 69
Contents Super Manual Revision Release Date February 23 Preface About This ManualManual Organization Advanced Serverboard Setup System SafetyAdvanced Chassis Setup BiosPreface Table of Contents Advanced Serverboard Setup System SafetyAdvanced Chassis Setup Appendices BiosPage Overview Chapter IntroductionProcessors Memory Serverboard FeaturesSerial ATA PCI Expansion SlotsOnboard Controllers/Ports Other FeaturesIntel E7520 Chipset System Block Diagram Server Chassis Features Headquarters Contacting SupermicroEurope Asia-PacificChapter Server Installation Preparing for SetupUnpacking the System Choosing a Setup Location Rack PrecautionsServer Precautions Rack Mounting Considerations Installing the System into a Rack Basic Installation ProcedureRack hardware optional Installing the Chassis Rails Installing with Rackmount KitInstalling the Server into the Rack Installing the Rack RailsInstalling the Server into a Rack Optional Rackmount Kit Installing the Server into a Telco RackAccessing the inside of the server Figure Checking the Serverboard SetupCheck the system memory Check all cable connections and airflow Installing add-on cardsChecking the Drive Bay Setup Page Control Panel Buttons Chapter System InterfaceControl Panel LEDs Page Page Electrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Installing the Onboard Battery Operating PrecautionsPrecautions Chapter Advanced Serverboard SetupHandling the Serverboard UnpackingServerboard Installation Installing the Heatsink BracketsInstalling the Serverboard Installing the Processors Processor and Heatsink InstallationInstalling the Heatsinks Installed processorInstalled heatsink Removing the Heatsink Connecting Cables Connecting Data CablesConnecting Power Cables I/O Ports Connecting the Control PanelInstalling Memory Dimm Installation See FigureMemory Support PCI card installation Adding PCI CardsPCI slots Super X6DLP-EG2 Layout Serverboard DetailsConnector Description Jumper Description Default SettingOnboard Indicators Description X6DLP-EG2 Quick ReferenceATX Power Connector Connector DefinitionsProcessor Power Connector Power LEDPower Fail LED NIC1/2 LEDsOverheat/Fan Fail LED Power Button Reset ButtonJLAN1/2 Ethernet Ports Chassis IntrusionUniversal Serial Bus USB0/1 Universal Serial Bus HeadersFan Headers Speaker/Power LED/Keylock Wake-On-RingWake-On-LAN Power Fault ConnectorSMB Power I2 C ATX PS/2 Keyboard and PS/2 Mouse PortsJLAN1/2 Enable/Disable Jumper SettingsExplanation Jumpers Cmos ClearPower Force On VGA Enable/DisableSMBus to PCI Slots Watch DogAlarm Reset Onboard IndicatorsJlan LEDs System Status LEDOnboard LED Indicators DS7, DS8 Onboard LED Indicators DS1, DS5Parallel Printer Port Header Parallel Port, Floppy, IDE and Sata Drive ConnectionsSata Connectors Floppy ConnectorIDE Drive Connectors Pin Definitions IDE1, IDE2 IDE ConnectorsPrecautions Chapter Advanced Chassis SetupStatic-Sensitive Devices Tools RequiredSystem Fans Control PanelSystem Fan Failure Installing a new fanReplacing System Cooling Fans Removing a fanDrive Bay Installation/Removal Accessing the Drive BaysSerial ATA Drive Installation CD-ROM Drive Installation Power Supply Failure Power SupplyAccessing the inside of the system Replacing the Power SupplyRemoving the power supply Installing a new power supplyPage How To Change the Configuration Data ChapterIntroduction Main Setup ProcessorsSystem Memory Configure Advanced CPU Settings Advanced SettingsCPU Configuration Sub-Menu System Time/System DateIDE Configuration Sub-Menu Combined Mode OperationIDE Configuration ATA Ports DefinitionType LBA/Large ModeBlock Multi-Sector Transfer A.R.T. For Hard disk drivesPCI/PnP Configuration Floppy ConfigurationPalette Snooping Allocate IRQ to PCI VGAPCI IDE BusMaster Offboard PCI/ISA IDE CardSuper IO Configuration Sub-Menu Advanced Chipset Settings Apci Configuration Power ConfigurationPCI/PCI Error Logging Watch Dog TimerPCI/PCI Express Error Logging Event Log ConfigurationRemote Access Configuration MPS ConfigurationPCI Express Configuration Serial Port Mode Remote AccessRedirection After Bios Post Sredir Memory Display DelaySystem Health Monitor USB ConfigurationSystem Fan Monitor Boot SettingsFan Speed Control Modes Fan1 Speed to Fan6 SpeedsBios Settings Configuration Hard Disk Drives Boot Device PriorityRemovable Drives CD/DVD DrivesChange Supervisor Password Security SettingsChange User Password Clear User PasswordExit Options Load Optimal DefaultsSaving Changes and Exit Discarding Changes and ExitLoad Fail-Safe Defaults Appendix a Bios Error Beep Codes Amibios Error Beep CodesBeep Code Error Message Description DS7/DS8 LED Post Codes LED IndicatorsUncompressed Initialization Codes Appendix B Bios Post Checkpoint CodesBootblock Recovery Codes Uncompressed Initialization Codes Checkpoint Appendix B Bios Post Checkpoint Codes Checkpoint A9h Aah Abh B0h B1h 00h Page Appendix C Software Installation Serial ATA SataIntel 6300ESB I/O Controller Hub Configuring Sata RAID Adaptec Sata HostRAID Controller DriverAdaptec RAID Configuration Utility ARC Using the Array Configuration Utility ACU Viewing Array Properties Managing ArraysCreating Arrays Deleting ArraysPage Assigning Array Properties RAID Levels Adding a Bootable Array Deleting a Bootable Array Initializing Disk DrivesTo initialize drives Page Page To rebuild an array Rebuilding ArraysTo access the disk utilities Using the Disk UtilitiesYou can choose from the following options Exiting the Adaptec RAID Configuration UtilityInstalling the ICH5R/6300 ESBDriver Installing Additional Drivers Installing Other Software Programs and DriversSupero Doctor Supero Doctor III Interface Display Screen-II Remote Control Page Appendix D System Specifications Power Supply WeightSystem Cooling System Input Requirements