Toshiba RBC-AMS41E Grille operation procedure, Detailed settings, Push the grille button

Page 10

Grille operation procedure

The functions will differ depending on the model and system.

*For further details, refer to the operating instructions of the air conditioner.

Operation

1Hold down the grille button (47) for at least 4 seconds.

The display transfers to the grille up/down screen, and the indoor units stop operating.

• The filter , grille up/down

and numeric display

blink.

 

*The “no function” display appears when the grille is not connected or the control settings have not been established correctly.

2Push the button (37), and select the indoor unit for which the grille is to be set.

Each time the button is pushed, the unit number on the numeric display changes.

*The fan of the selected indoor unit starts running, and the louver swings.

3Push the TEMP or button (49) to move the up/down grille.

When the button (49) is pushed, the up/down grille goes down slowly; conversely, when the button (49) is pushed, the up/down grille goes up.

If the up/down grille makes contact with an obstacle while it is going down, it stops.

Several seconds after the up/down grille rises and is neatly stowed in the air intake, the motor stops.

*The louver swings while the grille is going up or down.

*When the grille is stowed in the panel, this stowing operation is repeated 3 times to ensure that the grille is safely stowed away.

4Push the button (32) to stop the up/down grille.

The up or down movement of the up/down grille now stops.

If the button (32) is not pushed and the grille continues to move down, the grille will automatically stop when it has moved down to the distance set.

*To change the movement from up to down or vice versa, stop the up/down grille movement first, and then make the change.

5Push the grille button (47).

The grille operation mode is exited.

• The filter , grille up/down

and numeric display

goes off, and

blinks.

*While is blinking, there is no response to the keys of the remote controller even when they are pushed.

Correct operating procedures

Detailed settings

The functions will differ depending on the model and system.

For descriptions of the following settings, refer to the operating instructions of the air conditioner.

Changing the swing type

Fixing or releasing the louvers

Changing the save operation settings

G￿￿ ￿R￿￿ ￿U￿￿ ￿PEN

￿￿￿A ￿￿￿ ￿d.o .o .

MB FRIGO Grupa d.o.o., Bani 81, 10010 Zagreb, www.toshiba.hr, e-mail: toshiba@mbfrigo.hr

9

Image 10
Contents Manual del propietario Mando a distancia Remote controllerPBedienungsanleitung Contents Safety precautions ImpactParts and their functions Parts and their functions Setting the current day of the week and clock time Correct operating procedures Procedure for normal operationSymbol shown on the right Correct operating proceduresStarting the louver swing motion Now hold down the Temp button 49 for at least 4 seconds Self-cleaning operationsSave operations To release the save operation, push the button 38 againPush the Temp or button 49 to move the up/down grille Grille operation procedureDetailed settings Push the button 32 to stop the up/down grillePush the button How to set up the operation programsScheduled operations Push ButtonScheduled operations Example of setting up an operation program Scheduled operation setup Program check operation Error displaysCopying the program settings Push the button Again push the buttonEditing the operation programs Instructions for special holidaysHow to cancel the special holiday setting How to execute timer operations Timer operationsTimer operations Push the Time and buttons 40, and select the set timeTroubleshooting Selecting the functions using the DIP Selecting the remote controller functionsSwitches of the remote controller Selecting the remote controller functions