14. Ramp Control Menu

In the Ramp Control Menu speed and shutter ramps can be programmed. After enabling the Iris Control, also iris ramps can be performed. If a speed ramp is to be compensated by iris and shutter simultaneously, the ratio of both values can be mixed via the Compensation Mix Slider.

The actual status and position of the ramp is shown in the Ramp Display by the yellow arrows. When the ramp is performed, the arrows move along the ramp display from the start values to the end values providing a clear situational awareness of the running ramp.

The Exposure Calculator helps calculating the working T-stop. Simply measure the light on the set with your light meter and standard settings (e.g. 24fps, 250ASA) and enter the measured T-stop in the calculator (T- stop input window). The working T-stop that has to be set on the lens will then be computed and displayed in the Ramp Display. When the Iris Control is enabled, the iris will be set automatically to the correct value via the lens motor.

Status Window

Compensation

Mix Slider

Ramp

Display

Ramp

Time

Selector

T-stop input window for

Exposure Calculator

Ramp Control Menu

41

Image 41
Contents WRC-2 Page Order Numbers Contents Change Ramp Direction General Safety Instructions Safety InstructionsSpecific safety instructions Disclaimer Disclaimer Introduction Introduction Receiving SetupTransmitting Mounting the WRC-2 on the WMU-3 or WMU-2 WRC-2 & Arriflex 435 Xtreme / Advanced WRC-2 & Arricam Studio and LiteWRC-2 & other Arri Cameras WRC-2 & ArriflexDirect connection via the Camera Connector Wired ConfigurationsLCS Cables Connection via Universal Remote Controller URM-3WRC-2 & Arriflex 435 Xtreme / Advanced Possible Connections WRC-2 & Arricam Studio and Lite Possible ConnectionsWRC-2 & Arriflex 416 Possible Connections Introduction First Steps Powering Up The UnitUsing the Stylus Touchscreen Navigation General Operation and NavigationKey Navigation Lock/UnlockFunctions „Exit and „Edit Buttons Menu StructureStarting a Software Module Main MenuCamera Control Menu WRC-2 Settings MenuSettings Window Status Window Status Window Following values and settings are displayed Battery VoltageLDS e.g mm T1.9 Message & Warnings FieldEnter a user defined camera speed Choose from a preset camera speedCamera Control Menu Changing Camera Speed Delete items from the preset list Editing Preset Speeds & Change Camera DirectionAdd all default speed values Add a user defined speed valueEdit a specific camera shutter angle Choose from a preset camera shutter angleChanging Camera Mirror Shutter Add a user defined shutter angle value Editing Preset Camera Shutter AnglesAdd all default camera shutter values Camera Control Menu Filmcounter Sub-Menu Camera Control Options Sub-Menu To enter the Time Code Sub-Menu Camera Control Menu Time Code Sub-MenuTime Code on/off TCS Time Code SensitivityTime / User Bits Using a Lens without LDS Using a Lens with Lens Data SystemLens Manager Menu Lens Manager Menu FunctionsLoad Iris Tables Administer Iris Tables Create new Iris TablesRemove Iris Tables from the User Iris List Add Iris Tables from the User Folder SystemLens Manager MenuCreating new Iris Tables with the Iris Table Wizard StepName the Iris Table Intentionally left blank Ramp Control Menu Ramp Control Menu Enabling the Iris Control Programming a Ramp Compensation via the Mirror Shutter Ramp Control Menu Exposure CompensationCompensation via the iris Mixed Compensation via Shutter and IrisUse the Exposure Calculation To Enable the Exposure CalculationExposure Calculation Ramp Control Menu Compensation Free Style Enable „Compensation Free StyleRamp Options Set to DefaultChange Ramp Direction Safe and Load a Ramp Save a RampRamp Control Menu Ramp Example External Display Menu Updating the WRC-2 AppendixAdjusting the Knob Handwheel Service Menu Exit from AppCleaning Cleaning the Touchscreen File DialogNo Speed setting available Appendix TroubleshootingCommunication Problems Intentionally left blank Weight Technical Data DimensionsPower Supply Operating Temperature RangeArri Service Index Index Page Index