Phonetics Boat Remote user manual Call Progress, Voice, Beeper

Page 62

Boat Remote User’s Manual

dialing out. During this time (if the speaker is set to ON), the unit will recite an alarm message locally to indicate which input is in alarm. If someone on board acknowledges the alarm before the Call Delay time expires, the unit will not dial out.

2)Boat Remote checks the programmed dial out selection list for the current alarm condition and dials the first number on the list.

Dial Out

Call Progress

Boat Remote monitors call progress when dialing out. If Boat Remote dials out and encounters a busy signal or no answer, the unit hangs up, waits the programmed intercall delay time, and then dials the next phone number.

Boat Remote can make two types of phone calls, voice or beeper.

Voice

When dialing out to a phone number programmed as ‘voice’, Boat Remote waits for the phone to be answered, then recites its user- recorded identification message, then recites the alarm message.

Below is an example of what Boat Remote might say during a typical ‘voice’ dial out:

“Hello, this is (ID message). The water level is too high”

“Hello, this is (ID message). The water level is too high”

“Hello, this is (ID message). The water level is too high”

“Indicate you have received warning message.”

In this example, the number of Message Repetitions is three.

NOTE: If the call reaches an answering machine, the message will be recorded but Boat Remote will be talking over your outgoing message, so you will probably lose part of the first alarm message repetition.

Beeper

When dialing out to a phone number programmed as ‘beeper’, Boat Remote can leave a number (usually the unit’s own phone number) on the display of a numeric beeper.

IMPORTANT

When dialing out to a phone number programmed as ‘beeper’, Boat

62

Image 62
Contents User’s Manual Page Table of Contents What IS? key Alarm RecognitionCommunications Programming Monitoring Programming Examples Alarm Notification Dial Out Alarm AcknowledgmentMode Key Enter Key Down Arrow Key Arrow UP Key Code Key Boat Remote User’s Manual Safety Instructions FCC Requirements ViiiPhonetics, Inc Boat Remote User’s Manual Chapter Getting to Know Your Boat Remote Boat Remote User’s Manual Technical Support System Operating Mode LEDsInstallation Kit Boat Remote PackageBoat Remote User’s Manual Chapter Installation Connecting Power and Telephone Service High Water Float Switch To mount the switch, follow these steps Temperature Sensors Connecting Temperature SensorsConnecting the Bilge Pump Bilge PumpConnecting Accessories to the Security Input Output Connection to the Auxiliary InputChapter Programming Keys Keypad Keys and Their FunctionsRecording a Voice Message Temperature in the salon Maximum Number of Calls Program Max CallsUse the number keys Press Enter Refer to Rings Until Answer and TAD sections in this chapter Using the TAD Feature Program TADExample Listen to the sound level for programmed time Speaker Press Mode Press Enter Current Time & Today’s Date Programming the Dial Out Phone Numbers To toggle between voice or beeper press Mode Special Dialing 16105581212WPP3116655# Recognition Time not for Bilge #1 & #2 Input Mode Active, Off, Status OnlyInput Dial Out Phone Selection AC Power Input Phone Selection 1,2,4,6 Programming Boat Remote User’s Manual Press Enter Display will reflect your selection Boat Remote User’s Manual Programming OFF Programming Phone Selection 1,2,4,6 Press High Water Auxiliary Input Press Auxiliary Security Input Press Security Verifying Programming Outside temperature is 74F Boat Remote User’s Manual Alarm Notification Chapter OperationBeeper Call ProgressVoice ‘555’ Acknowledgment Code LocalRemote Voice Dial Out ‘999’ Acknowledgment CodeBeeper Dial Out Automatic Alarm Acknowledgment Max Calls Communications ProgrammingInput Alarm Limits Rec. Time Mode Alarm Notification Error AcknowledgmentAC power is off Boat Remote repeats the message The battery voltage is low Status Report Boat Remote User’s Manual Chapter Troubleshooting Problem The Boat Remote fails to detect an alarm conditionProblem The Boat Remote fails to dial out Problem The temperature reading is inaccurate Problem The temperature reading is -20.1F or -29.1CProblem The temperature reading is 160.1F or 72.1C Problem The bilge pump input does not count on/off cycles Problem False power failure alarmsProblem The Boat Remote does not recognize power failure Problem The Boat Remote does not recognize any alarm Boat Remote User’s Manual TEMP#1, #2, & #3 Bilge #1 & #2Mode Key Checking Your Boat Remote for Proper Op- eration Boat Remote User’s Manual Appendix C Engineering Specifications III. Communications Features IV. Programming VI. Enclosure, Environmental and Power Marine Division Tryens Road Aston, PA Phone 610558-2700 FAX Boat Remote User’s Manual Appendix D Returning Your Unit for Repair Boat Remote User’s Manual