Chapter 5: Troubleshooting
SOLUTION: Replace the AC power fuse, see Fig 2.2 in Chapter 2. The fuse is rated at 1.5 Amps and is size 2AG.
PROBLEM: The Boat Remote does not recognize any alarm.
CAUSE: The Boat Remote is in standby mode.
SOLUTION: Press the MODE button to change to
AWAY MODE.
PROBLEM: The LCD display says that the 3V lithium battery is low.
CAUSE: The internal battery that backs up the voice messages is low.
SOLUTION: Replace the battery while the unit is on to preserve the voice messages. The battery is a Tadiran
If the solutions offered above do not appear to correct the problem, apply the following steps in the order shown.
*Remove the lower access panel.
*Move the power switch to the OFF position.
*Wait one minute for the Boat Remote to completely power down.
*Move the power switch to the ON position.
If the Boat Remote appears to have corrupted programming information, you may reset the unit to the factory default settings by entering the following key sequence: 092793.
77