Klark Teknik DN9344E, DN9340E manual To Bypass the parametric EQ on the current channel

Page 17

HELIX DN9340E/DN9344E Remote Control Software

User Guide

To Bypass the parametric EQ on the current channel

Tick the †Bypass check box in the upper Parametric tab.

To add a PEQ section to the graph

1Click on the

Add

button in the lower Parametric tab. A PEQ

panel with Level, frequency and Q is added to the tab (shown right) and a target appears on the graph at 1kHz.

2Left click on the target and drag it to the required frequency and dB level. Right click on the target and drag the mouse up/down (the target remains still) to increase/decrease the width of the PEQ section, that is, by adjusting the Q value. The values in the PEQ panel track the target.

3If required, fine tune settings by scrolling the PEQ panel Frequency, Level and Q fields.

Hint Adjusting PEQ positions: The target provides quick but coarse adjustment, the scrolls enable fine adjustment. If you know the exact values you wish to apply, it may be quicker to type the values into the PEQ panel. Frequencies in kHz should be entered with a ‘k’ suffix, that is, 12.5k for 12.5 kHz. Frequencies will be automatically adjusted to the nearest valid increment.

To activate the target at an existing PEQ section

Click anywhere on its PEQ panel, but note that if you click on the very bottom of the panel, you also click the Out field and thus change the in/out status. The selected panel becomes highlighted and the target ‘switches’ to the associated PEQ section.

The target cannot be ‘switched’ to another PEQ by clicking on the graphic (this would conflict with its function as a repositioning control for the underlying PEQ section).

Note

The order of the PEQ panels will not necessarily mirror the order of the PEQ sections on the graph, as targets can be moved along the frequency axis to suit requirements.

To switch a PEQ section out of the circuit

PEQ In

1 Tick on the † Out check box at the bottom of the respective PEQ panel.

The PEQ section is faded to grey on the graph and its contribution is removed from the overall frequency response. The target stays on the PEQ section so that the PEQ can still be adjusted while switched out.

2 To switch the PEQ section in again, clear the † Out check box.

PEQ out

To remove a PEQ section from the graph

1Move the target to the PEQ section you wish to remove by clicking on its PEQ panel. Click the Remove button in the Parametric Shaping tab.

2At the prompt, click

Yes

to confirm the removal the PEQ or

No

to cancel.

The PEQ section is removed and the remaining PEQ panels re-numbered, if required.

17 of 65

Image 17
Contents Helix DN9340E/DN9344E Contact Details Helix DN9340E/DN9344E Remote Control SoftwareContents STORING/RECALLING Memory Settings Introducing the Helix Remote Control Software Midas Elgar Library Manager Shell available at Minimum System RequirementsMicrosoft .NET Framework 1.1 available at Software Installation Helix DN9340E/DN9344E Remote Control Software To add-in an Helix RCS device to the Elgar Library Manager Opening Helix RCS within the Elgar Library ManagerQuick Tour of the DN9340 Device Views To quickly switch to a different view on the same channelDN9340 Device Workspace To quickly switch to a different view on the other channel Specify the Helix unit details in the upper Home tab Network IdentificationTo link the channels for identical operation Linking and Bypassing ChannelsSpecify channel details in the lower Home tab To specify the EQ mode for the current channel To switch to the Graphic Equalisation viewGraphic Equalisation GraphicTo adjust a group of faders together To adjust a fader levelTo reset all faders to zero To switch a fader out of the circuitTo set the Parametric EQ mode for the channel To switch to the Parametric Equalisation viewParametric Equalisation ParaTo Bypass the parametric EQ on the current channel To switch a PEQ section out of the circuitTo add a PEQ section to the graph To activate the target at an existing PEQ sectionTo set the Dynamic EQ mode for the channel To switch to the Dynamic Equalisation viewDynamic Equalisation DynamicTo activate the target on the other Dynamic To Bypass the Dynamic EQ on the current channelTo shape a Dynamic EQ section To switch to the Filter view To switch a Dynamic section out of the circuitFilters FilterTo switch a Filter out of the circuit At the Filter Mode tabTo Bypass all the Filters on the current channel To add a Filter to the graphFastNav Screen To switch to the FastNav screenBuilding your Network Remotely Helix DN9340E/DN9344E Remote Control Software Copy Channels Screen To copy settings from one device to anotherHint Global Graphic ScreenHelix DN9340E/DN9344E unit interconnections Connecting the Helix DN9340/DN9344E units in a daisy chainOverview Ethernet connection standard Ethernet ConnectionTo configure an Ethernet device and assign a port to it Ethernet connection wireless optionConfiguring the Network Devices Helix DN9340E/DN9344E Remote Control Software Click OK IP Addressing Wireless RoutingIP settings Access PointWireless Network Settings Security SettingsWireless Network Connections screen Wireless CardWireless network properties window Helix DN9340E/DN9344E Remote Control Software If your laptop/PC has a firewall Serial Connection Option Connection ProcedureSerial connection details Laptop/PC Cable/Converter Required Unit ConnectionHelix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software To find all ports on your system System Configuration WindowFinding ports and device names To find new devices attached to your PC Port Configuration screenHelix DN9340E/DN9344E Remote Control Software Communications Overview Working OnlineOnline Operation Version UpdateTo take a unit offline To cancel online connection during pollingTo check the online status of the Devices in the network To set the Rapide unit online/offlineTroubleshooting Activity IndicatorsTo take the entire network offline All Units OfflineTo assign solo sources to Helix channels To open the System Solo Tracking Setup screenSolo Tracking Operation Helix DN9340E/DN9344E Remote Control Software Function Locking Protecting System SettingsTo change lockout settings Change Password To change the current passwordMemory Working with Individual AddIns To switch to the Memory viewHelix DN9340E/DN9344E Remote Control Software To write all the Memories from the AddIn Device to the unit To retrieve all the Memories from a Unit to the AddIn DeviceTo Read/Write All Memories from/to multiple units Global Memory ManagementTo open the global Memory Management screen To return to the FastNav screen, click Switch to the Store \ Recall Memory tabRecall From Memory Store To Memory AddIn Glossary of Terms and AbbreviationsSsid To connect a single non-Ethernet unit USB to rear panel Remote Control Connection OptionsTo connect a single unit USB to front panel Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Setting up the Lantronix UDS1100 Converter Web Configuration and Telnet Configuration tabs To connect up a Helix RCS Ethernet System Apply SettingsConnecting the system equipment LAN
Related manuals
Manual 76 pages 248 b