Klark Teknik DN9344E, DN9340E manual Introducing the Helix Remote Control Software

Page 5

HELIX DN9340E/DN9344E Remote Control Software

User Guide

1INTRODUCING THE HELIX REMOTE CONTROL SOFTWARE

The HELIX Equaliser Remote Control Software (HELIX RCS) enables engineers to remotely program a network of up to 64 HELIX equaliser channels from a laptop or PC for onward downloading to the DN9340E or DN9344E units at a venue. This means that programming can be done in advance of a show from home or en-route, leaving more time for fine-tuning.

At the venue, the settings can be quickly downloaded to the equaliser network. Thereafter, a HELIX RCS laptop/PC can be used for real-time control of the slave equaliser network during both set-up and performance. Using the HELIX RCS in place of a DN9340E offers an enhanced visual overview of slave performance, as well as significant time-savings in switching between slave units, navigating equalisation views and adjusting settings. Furthermore, for optimal control during set-up, the laptop/PC can be set up to communicate with the slave network over a wireless connection, leaving the engineer free to move around the venue while adjusting the equalisation settings. For performance, Ethernet communication is used, although there is an option for conventional serial RS-232, if required. Settings can also be uploaded from the DN9340E/DN9344E Equalisers to the HELIX RCS.

In addition to the active settings, HELIX RCS can also be used to remotely program all the equaliser memories, and that includes the 32 lockable Preset (flash) memories, which can only be programmed from an external computer.

The HELIX RCS runs as an AddIn to the Midas Klark Teknik ELGAR Library Manager, enabling you to work on settings for your equaliser devices alongside other Midas or Klark Teknik devices, for example, a console, and save them all in a single show file. The show file can then be reused from venue to venue. In addition, you can minimise time and effort by copying settings between the HELIX RCS AddIn devices.

Please note that, for the purposes of this manual, a HELIX DN9340E or DN9344E unit is the actual physical version connected to the system and an RCS unit is a unit in HELIX DN9340E/DN9344E RCS. Also, some of the screenshots in the manual may appear slightly different to those on your screen due to configuration and status of the system, units and your laptop/PC.

Note

Earlier HELIX DN9340 and DN9344 devices (non-E) may be connected to the network and controlled using the HELIX DN9340E/DN9344E RCS, provided that the connection to these devices is in accordance with Appendix 9.2 of this User Guide.

5 of 65

Image 5
Contents Helix DN9340E/DN9344E Contact Details Helix DN9340E/DN9344E Remote Control SoftwareContents STORING/RECALLING Memory Settings Introducing the Helix Remote Control Software Midas Elgar Library Manager Shell available at Minimum System RequirementsMicrosoft .NET Framework 1.1 available at Software Installation Helix DN9340E/DN9344E Remote Control Software To add-in an Helix RCS device to the Elgar Library Manager Opening Helix RCS within the Elgar Library ManagerQuick Tour of the DN9340 Device Views To quickly switch to a different view on the same channelDN9340 Device Workspace To quickly switch to a different view on the other channel Specify the Helix unit details in the upper Home tab Network IdentificationTo link the channels for identical operation Linking and Bypassing ChannelsSpecify channel details in the lower Home tab To specify the EQ mode for the current channel To switch to the Graphic Equalisation viewGraphic Equalisation GraphicTo adjust a group of faders together To adjust a fader levelTo reset all faders to zero To switch a fader out of the circuitTo set the Parametric EQ mode for the channel To switch to the Parametric Equalisation viewParametric Equalisation ParaTo Bypass the parametric EQ on the current channel To switch a PEQ section out of the circuitTo add a PEQ section to the graph To activate the target at an existing PEQ sectionTo set the Dynamic EQ mode for the channel To switch to the Dynamic Equalisation viewDynamic Equalisation DynamicTo activate the target on the other Dynamic To Bypass the Dynamic EQ on the current channelTo shape a Dynamic EQ section To switch to the Filter view To switch a Dynamic section out of the circuitFilters FilterTo switch a Filter out of the circuit At the Filter Mode tabTo Bypass all the Filters on the current channel To add a Filter to the graphFastNav Screen To switch to the FastNav screenBuilding your Network Remotely Helix DN9340E/DN9344E Remote Control Software Copy Channels Screen To copy settings from one device to anotherHint Global Graphic ScreenHelix DN9340E/DN9344E unit interconnections Connecting the Helix DN9340/DN9344E units in a daisy chainOverview Ethernet connection standard Ethernet ConnectionTo configure an Ethernet device and assign a port to it Ethernet connection wireless optionConfiguring the Network Devices Helix DN9340E/DN9344E Remote Control Software Click OK IP Addressing Wireless RoutingIP settings Access PointWireless Network Settings Security SettingsWireless Network Connections screen Wireless CardWireless network properties window Helix DN9340E/DN9344E Remote Control Software If your laptop/PC has a firewall Serial Connection Option Connection ProcedureSerial connection details Laptop/PC Cable/Converter Required Unit ConnectionHelix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software To find all ports on your system System Configuration WindowFinding ports and device names To find new devices attached to your PC Port Configuration screenHelix DN9340E/DN9344E Remote Control Software Communications Overview Working OnlineOnline Operation Version UpdateTo take a unit offline To cancel online connection during pollingTo check the online status of the Devices in the network To set the Rapide unit online/offlineTroubleshooting Activity IndicatorsTo take the entire network offline All Units OfflineTo assign solo sources to Helix channels To open the System Solo Tracking Setup screenSolo Tracking Operation Helix DN9340E/DN9344E Remote Control Software Function Locking Protecting System SettingsTo change lockout settings Change Password To change the current passwordMemory Working with Individual AddIns To switch to the Memory viewHelix DN9340E/DN9344E Remote Control Software To write all the Memories from the AddIn Device to the unit To retrieve all the Memories from a Unit to the AddIn DeviceTo Read/Write All Memories from/to multiple units Global Memory ManagementTo open the global Memory Management screen To return to the FastNav screen, click Switch to the Store \ Recall Memory tabRecall From Memory Store To Memory AddIn Glossary of Terms and AbbreviationsSsid To connect a single non-Ethernet unit USB to rear panel Remote Control Connection OptionsTo connect a single unit USB to front panel Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Setting up the Lantronix UDS1100 Converter Web Configuration and Telnet Configuration tabs To connect up a Helix RCS Ethernet System Apply SettingsConnecting the system equipment LAN