Klark Teknik DN9344E, DN9340E manual Global Graphic Screen, Hint

Page 25

HELIX DN9340E/DN9344E Remote Control Software

User Guide

5Choose Apply to apply the changes and keep the screen open for further copying. or

Choose OK to apply changes and close the screen.

Note

Hint

If you see the following message, this feature is not available as there are lock flags active.

If copying basic settings to most channels, use Select All to tick all channels in the destination list, then clear check boxes as required. When starting a new selection, use Reset All to quickly clear all previous ticks.

6.4Global Graphic Screen

The Global Graphic screen, accessed from the Global Graphic

button in FastNav®, has 31 fader controls.

These faders provide global gain adjustment of the 31 bands of the 1/3 octave equaliser across all channels and correspond to the ones found on the Graphic Equalisation view, accessed from the Graphic tabs.

Operation of a fader on the Global Graphic screen causes the corresponding fader on all channels to be adjusted by the same amount. For example, if you adjust the 100k fader on the Global Graphic screen by +8dB, then each channel’s 100k fader will be increased by +8dB. This is irrespective of the position of the channel faders before adjustment. However, if a channel fader is at or near its maximum or minimum value it may not be able to accept the full amount of adjustment; in this case it will be adjusted to maximum or minimum.

Once selected, the Global Graphic screen remains on top of the other ELGAR screens and operation is restricted solely to the Global Graphic faders. Changes to these faders are reflected in the graphs on the Home, Graphic and Memory screens, and also the Graphic’s faders. You can reposition the Global Graphic screen (see diagram below) to view more easily what is underneath, but to edit the other ELGAR screens you must close the Global Graphic screen first by clicking on the Close button.

25 of 65

Image 25
Contents Helix DN9340E/DN9344E Contact Details Helix DN9340E/DN9344E Remote Control SoftwareContents STORING/RECALLING Memory Settings Introducing the Helix Remote Control Software Microsoft .NET Framework 1.1 available at Minimum System RequirementsMidas Elgar Library Manager Shell available at Software Installation Helix DN9340E/DN9344E Remote Control Software To add-in an Helix RCS device to the Elgar Library Manager Opening Helix RCS within the Elgar Library ManagerDN9340 Device Workspace To quickly switch to a different view on the same channelQuick Tour of the DN9340 Device Views To quickly switch to a different view on the other channel Specify the Helix unit details in the upper Home tab Network IdentificationSpecify channel details in the lower Home tab Linking and Bypassing ChannelsTo link the channels for identical operation To specify the EQ mode for the current channel To switch to the Graphic Equalisation viewGraphic Equalisation GraphicTo adjust a group of faders together To adjust a fader levelTo reset all faders to zero To switch a fader out of the circuitTo set the Parametric EQ mode for the channel To switch to the Parametric Equalisation viewParametric Equalisation ParaTo Bypass the parametric EQ on the current channel To switch a PEQ section out of the circuitTo add a PEQ section to the graph To activate the target at an existing PEQ sectionTo set the Dynamic EQ mode for the channel To switch to the Dynamic Equalisation viewDynamic Equalisation DynamicTo shape a Dynamic EQ section To Bypass the Dynamic EQ on the current channelTo activate the target on the other Dynamic To switch to the Filter view To switch a Dynamic section out of the circuitFilters FilterTo switch a Filter out of the circuit At the Filter Mode tabTo Bypass all the Filters on the current channel To add a Filter to the graphBuilding your Network Remotely To switch to the FastNav screenFastNav Screen Helix DN9340E/DN9344E Remote Control Software Copy Channels Screen To copy settings from one device to anotherHint Global Graphic ScreenOverview Connecting the Helix DN9340/DN9344E units in a daisy chainHelix DN9340E/DN9344E unit interconnections Ethernet connection standard Ethernet ConnectionConfiguring the Network Devices Ethernet connection wireless optionTo configure an Ethernet device and assign a port to it Helix DN9340E/DN9344E Remote Control Software Click OK IP Addressing Wireless RoutingIP settings Access PointWireless Network Settings Security SettingsWireless network properties window Wireless CardWireless Network Connections screen Helix DN9340E/DN9344E Remote Control Software If your laptop/PC has a firewall Serial Connection Option Connection ProcedureSerial connection details Laptop/PC Cable/Converter Required Unit ConnectionHelix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Finding ports and device names System Configuration WindowTo find all ports on your system To find new devices attached to your PC Port Configuration screenHelix DN9340E/DN9344E Remote Control Software Communications Overview Working OnlineOnline Operation Version UpdateTo take a unit offline To cancel online connection during pollingTo check the online status of the Devices in the network To set the Rapide unit online/offlineTroubleshooting Activity IndicatorsTo take the entire network offline All Units OfflineSolo Tracking Operation To open the System Solo Tracking Setup screenTo assign solo sources to Helix channels Helix DN9340E/DN9344E Remote Control Software To change lockout settings Protecting System SettingsFunction Locking Change Password To change the current passwordMemory Working with Individual AddIns To switch to the Memory viewHelix DN9340E/DN9344E Remote Control Software To write all the Memories from the AddIn Device to the unit To retrieve all the Memories from a Unit to the AddIn DeviceTo open the global Memory Management screen Global Memory ManagementTo Read/Write All Memories from/to multiple units Recall From Memory Store To Memory Switch to the Store \ Recall Memory tabTo return to the FastNav screen, click AddIn Glossary of Terms and AbbreviationsSsid To connect a single unit USB to front panel Remote Control Connection OptionsTo connect a single non-Ethernet unit USB to rear panel Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Helix DN9340E/DN9344E Remote Control Software Setting up the Lantronix UDS1100 Converter Web Configuration and Telnet Configuration tabs Connecting the system equipment Apply SettingsTo connect up a Helix RCS Ethernet System LAN