HELIX DN9340E/DN9344E Remote Control Software
User Guide
8.2Global Memory Management
Memories can be simultaneously recalled or stored to/from multiple units from the global Memory Management screen.
To open the global Memory Management screen
Switch to the FastNav® screen and choose
Memory Management .
The screen shown below is opened. It has two tabs (of similar appearance) as follows:
Read \ Write Memories - for globally downloading or uploading all user and preset memories between AddIns and their respective slave units.
Store \ Recall Memory - for uploading or downloading a specific User Memory between AddIns and their respective slave units.
The synchronise direction is specified here for global uploads and downloads
|
|
|
|
|
| The status bars show | |
|
| progress through | |
|
| the list (above) and | |
|
| ||
All or a subset of | at the current unit | ||
Units can be | (below). | ||
selected for |
|
| |
updating |
|
|
To Read/Write All Memories from/to multiple units
1Switch to the Read \ Write Memories tab.
2Tick the check box of each Unit for which memories should be downloaded/uploaded.
Hint | If uploading/downloading to most units, use | Select All | to tick all units in the destination | |
| list, then clear check boxes as required. When starting a new selection, use | Deselect All | ||
| quickly clear all previous ticks. |
to
3 | Set the Synchronisation to Get All Initial values from the Audio System or Set All Initial |
| values from Computer, as required. |
4Ensure the Preset Memories are unlocked at the relevant Units.
5Click Read All Memories or Write All Memories as required.
53 of 65