MENU

6.9 RECORD SETTING MENU

RECORD SETTING MENU

NORMAL RECORD

SPEED

: 50 IPS

QUALITY

: STANDARD

DISK FULL

: REWRITE

ALARM RECORD

OPERATION ON

SPEED: 50 IPS

QUALITY : STANDARD

PRE-ALARM RECORD

OPERATION ON

PREMANENT RECORD

OPERATION

: ON

SPEED

: 0,01 IPS

In NORMAL RECORDING MENU we define

(1)NORMAL RECORD:

SPEED : Choose the normal recording speed. Maximum 60 (NTSC) / 50 (PAL).

QUALITY: Define the video picture’s quality by selecting a compression rate. There are six quality levels for recording

LOWER

: 15 KB

LOW

: 19 KB

BASIC

: 23 KB

STANDARD : 27 KB

HIGH

: 31 KB

SUPERIOR

: 35 KB

DISK FULL: Set REWRITE or STOP when HDD is full.

(2)ALARM RECORD (for Alarm In and Motion detection):

OP (Operation): Select ON to activate or OFF to deactivate alarm recording.

SPEED : Choose the alarm and motion recording speed. Maximum 60 (NTSC) / 50 (PAL).

QUALITY: Define the video picture’s quality by selecting a compression rate.

NOTE: The recording rates are for the total system. The single camera recording rate is: Camera recording rate = System recording rate / Number of connected cameras Example: Recording rate 50 IPS, 6 connected cameras: ~ 8,3 IPS / camera

NOTE: For alarm recording, see also remarks in (4) PERMANENT RECORDING.

Turn the JOG dial clockwise or counter-clockwise to select the options.

Press ENTER key to confirm the option and move to next column.

ENTER

Press MENU key to return to Main Menu, press again to leave Set up Menu.

MENU

20

Image 25
Contents V1.09 EDSR-1600Safety Precautions Power Disconnect Important Safeguards Important SafeguardsTable of Contents Product Overview Main FeaturesProduct Overview Specifications SpecificationsBack Panel Connections Back Panel ConnectionsON/OFF AC100~240VAlarm I/O Refer pin assignment in Appendix-C, System Connection Before InstallationSystem Connection Front Panel Keypads Front Panel KeypadsShuttle Ring and JOG Dial Chanel KeysIR Remote Controller receiver Operation Press Menu key to enter SET UP MenuOperation Insert a HDD IDE for Video StorageMenu Flow Menu flowMatrix CLOCK/LANGUAGE Setting Menu , we define Clock Setting MenuMenu Language English First SUN October Change Daylight Saving TimeWrong Timer Setting MenuCorrect Sequence Setting MENU, we define for Main Monitor Sequence Setting MenuTitle Setting Menu we define Title Setting MenuCovert Setting Menu we define Covert Setting MenuDefault setting is OFF for all cameras Alarm Recording MENU, we define Alarm Record Setting MenuMotion Record Setting Menu we define Motion Setting MenuOP Operation Default OFF HIT 1-9/16 to Manual Edit Record Setting Menu Permanent Recording PRE-ALARM Record with Alarm In and MotionPermanent record option Operation on or OFF Important NoteNetwork Setting MENU, we define Network Setting MenuAdmin USER-NAME Password LevelGeneral GuestControl Setting MENU, we define Control Setting MenuBuzzer Setting Menu Picture Size Archive Setting MenuTime Stamp Water MarkDialog Matrix Setting MenuCH, DWELL, Event Disk Menu PTZ Setting Menu PTZ Setting MenuExample Connection ED-2250 Dome to EDSR600/900/1600 Pelco D DIP switch 501 at ED2250RS-485 Connection ED-2250 dome RS-232 Connection ED2250 Dome System Setting MENU, we define System Setting MenuPlay with Audio AUDIO-1, AUDIO-2 Recording Alarm RecordingInstant Recording Permanent Recording Timer RecordingNormal Playback Playing BackPlay EnterSearch Playback Search PlaybackSegment List search playback SearchHDD2 Alarm List search playbackDate/Time Search Playback Still Image Copy Data ExportPause Copy Menu Copy to Movie FileExport Event LOG List AlarmDisplay CallMonitor Views / Operation Main Monitor Mode Display ZoomCall / Matrix monitors Sequence Call / Matrix Monitors11.1 RS-485 Remote Control Remote ControlInstallation example 2 remote operators, 1 Edsr 900, 1 Edsr RJ45 RS -485 pin assignmentWiring diagram multiple keyboard control With EDSR-1600 recorder IR Remote Controller optionalView From Internet/Intranet Main Screen View From Internet/Intranet View From Internet/Intranet PTZ Camera PresetRUN User Rights Password ProtectionOperation Appendix-A SpecificationsNtsc ? When Recording with 160GB HDDPicture Quality KB Basic Standard High SuperiorAppendix-B ? When Recording with 320GB HDDUnit Hour System storageGB Recording Pin assignment of the D-SUB 9-pin connector Appendix C Serial Interface SpecificationsTransmission setting RS-232 pin assignmentSample control code packets Remote Control ProtocolLength Byte Format of message packet is as followsReceiver ID OPcode Opcode Byte & Data bytesRemote keys OPcode=0x4B Checksum Byte Matrix command OPcode=0x4DAppendix-D Alarm I/O pin assignmentDVR EverFocus