EverFocus EDSR-900, EDSR-1600 instruction manual Safety Precautions

Page 2

Safety Precautions

CAUTION

DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING

TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK,

DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

Safety Precautions

Refer all work related to the installation of this product to qualified service personnel or system installers.

Do not block the ventilation opening or slots on the cover.

Do not drop metallic parts through slots.This could permanently damage the appliance. Turn the power off immediately and contact qualified service personnel for service.

Do not attempt to disassemble the appliance.To prevent electric shock, do not remove screws or covers. There are no user-serviceable parts inside. Contact qualified service personnel for maintenance. Handle the appliance with care. Do not strike or shake, as this may damage the appliance.

Do not expose the appliance to water or moisture, nor try to operate it in wet areas. Do take immediate action if the appliance becomes wet. Turn the power off and refer servicing to qualified service personnel. Moisture may damage the appliance and also cause electric shock.

Do not use strong or abrasive detergents when cleaning the appliance body. Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove,use a mild detergent and wipe gently.

Do not overload outlets and extension cords as this may result in a risk of fire or electric shock.

Do not operate the appliance beyond its specified temperature, humidity or power source ratings. Do not use the appliance in an extreme environment where high temperature or high humidity exists. Use the appliance at temperature within 0o C ~ +40oC and a humidity below 90%. The input power source for this appliance is AC100~240V

Image 2
Contents EDSR-1600 V1.09Safety Precautions Power Disconnect Important Safeguards Important SafeguardsTable of Contents Product Overview Main FeaturesProduct Overview Specifications SpecificationsON/OFF Back Panel ConnectionsBack Panel Connections AC100~240VAlarm I/O Refer pin assignment in Appendix-C, System Connection Before InstallationSystem Connection Shuttle Ring and JOG Dial Front Panel KeypadsFront Panel Keypads Chanel KeysIR Remote Controller receiver Operation Press Menu key to enter SET UP MenuOperation Insert a HDD IDE for Video StorageMenu flow Menu FlowMatrix Menu Language English Clock Setting MenuCLOCK/LANGUAGE Setting Menu , we define Daylight Saving Time First SUN October ChangeCorrect Timer Setting MenuWrong Sequence Setting Menu Sequence Setting MENU, we define for Main MonitorTitle Setting Menu Title Setting Menu we defineDefault setting is OFF for all cameras Covert Setting MenuCovert Setting Menu we define Alarm Record Setting Menu Alarm Recording MENU, we defineOP Operation Default OFF Motion Setting MenuMotion Record Setting Menu we define HIT 1-9/16 to Manual Edit Record Setting Menu Permanent record option Operation on or OFF PRE-ALARM Record with Alarm In and MotionPermanent Recording Important NoteNetwork Setting Menu Network Setting MENU, we defineGeneral USER-NAME Password LevelAdmin GuestControl Setting Menu Control Setting MENU, we defineBuzzer Setting Menu Time Stamp Archive Setting MenuPicture Size Water MarkCH, DWELL, Event Matrix Setting MenuDialog Disk Menu PTZ Setting Menu PTZ Setting MenuRS-485 Connection ED-2250 dome Pelco D DIP switch 501 at ED2250Example Connection ED-2250 Dome to EDSR600/900/1600 RS-232 Connection ED2250 Dome Play with Audio AUDIO-1, AUDIO-2 System Setting MenuSystem Setting MENU, we define Instant Recording Alarm RecordingRecording Timer Recording Permanent RecordingPlay Playing BackNormal Playback EnterSegment List search playback Search PlaybackSearch Playback SearchAlarm List search playback HDD2Date/Time Search Playback Pause Copy Data ExportStill Image Copy Copy to Movie File MenuDisplay AlarmExport Event LOG List CallCall / Matrix monitors Main Monitor Mode Display ZoomMonitor Views / Operation Call / Matrix Monitors SequenceInstallation example 2 remote operators, 1 Edsr 900, 1 Edsr Remote Control11.1 RS-485 Remote Control RJ45 RS -485 pin assignmentWiring diagram multiple keyboard control IR Remote Controller optional With EDSR-1600 recorderView From Internet/Intranet Main Screen View From Internet/Intranet View From Internet/Intranet RUN PresetPTZ Camera Operation Password ProtectionUser Rights Specifications Appendix-APicture Quality KB ? When Recording with 160GB HDDNtsc Basic Standard High SuperiorUnit Hour System storageGB Recording ? When Recording with 320GB HDDAppendix-B Transmission setting Appendix C Serial Interface SpecificationsPin assignment of the D-SUB 9-pin connector RS-232 pin assignmentRemote Control Protocol Sample control code packetsFormat of message packet is as follows Length ByteReceiver ID Remote keys OPcode=0x4B Opcode Byte & Data bytesOPcode Matrix command OPcode=0x4D Checksum ByteDVR Alarm I/O pin assignmentAppendix-D EverFocus