MENU

(3)PRE-ALARM RECORD: (with Alarm In and Motion)

Pre-alarm duration is depending on recording quality (about 8-15 seconds).

OP (Operation): Select ON to activate or OFF to deactivate pre-alarm recording.

(4)PERMANENT RECORDING:

This recording mode is used for continuous recording in the quality of NORMAL RECORD settings.

Permanent record option: Operation: ON or OFF

Speed : 0.01 IPS, 0.3 IPS, 0.5 IPS, 1 IPS, 5 IPS, 10 IPS, 15 IPS, 20 IPS, 30 IPS, and 60 IPS.

IMPORTANT NOTE:

This mode is recommended in combination with alarm records (alarm contacts or motion alarm). If only alarm recording is active, the hard disk capacity is not used optimal because every alarm record opens a new segment on the hard disk. Depending on the alarm settings (duration, quality), this segment is not used totally and results in the total EDSR recording time being less than expected.

By activating a NORMAL or PERMANENT recording with low recording rate - from version 1.08 the EDSR900/1600 also supports 0,01 IPS (1 picture every 100 seconds) -, this effect can be avoided. All records will continuously be written in one segment and the Hard Disk is used up to its full capacity.

When device had been set to be “PERMANENT” recording, and the device will follow “PERMANENT” setting when Rec bottom not been pushed(Device power on). If users push the Rec bottom, and it is “Normal” recording type.

Turn the JOG dial clockwise or counter-clockwise to select the options.

Press ENTER key to confirm the option and move to next column.

ENTER

Press MENU key to return to Main Menu, press again to leave Set up Menu.

MENU

21

Image 26
Contents EDSR-1600 V1.09Safety Precautions Power Disconnect Important Safeguards Important SafeguardsTable of Contents Product Overview Main FeaturesProduct Overview Specifications SpecificationsON/OFF Back Panel ConnectionsBack Panel Connections AC100~240VAlarm I/O Refer pin assignment in Appendix-C, System Connection Before InstallationSystem Connection Shuttle Ring and JOG Dial Front Panel KeypadsFront Panel Keypads Chanel KeysIR Remote Controller receiver Operation Press Menu key to enter SET UP MenuOperation Insert a HDD IDE for Video StorageMenu flow Menu FlowMatrix Menu Language English Clock Setting MenuCLOCK/LANGUAGE Setting Menu , we define Daylight Saving Time First SUN October ChangeCorrect Timer Setting MenuWrong Sequence Setting Menu Sequence Setting MENU, we define for Main MonitorTitle Setting Menu Title Setting Menu we defineDefault setting is OFF for all cameras Covert Setting MenuCovert Setting Menu we define Alarm Record Setting Menu Alarm Recording MENU, we defineOP Operation Default OFF Motion Setting MenuMotion Record Setting Menu we define HIT 1-9/16 to Manual Edit Record Setting Menu Permanent record option Operation on or OFF PRE-ALARM Record with Alarm In and MotionPermanent Recording Important NoteNetwork Setting Menu Network Setting MENU, we defineGeneral USER-NAME Password LevelAdmin GuestControl Setting Menu Control Setting MENU, we defineBuzzer Setting Menu Time Stamp Archive Setting MenuPicture Size Water MarkCH, DWELL, Event Matrix Setting MenuDialog Disk Menu PTZ Setting Menu PTZ Setting MenuRS-485 Connection ED-2250 dome Pelco D DIP switch 501 at ED2250Example Connection ED-2250 Dome to EDSR600/900/1600 RS-232 Connection ED2250 Dome Play with Audio AUDIO-1, AUDIO-2 System Setting MenuSystem Setting MENU, we define Instant Recording Alarm RecordingRecording Timer Recording Permanent RecordingPlay Playing BackNormal Playback EnterSegment List search playback Search PlaybackSearch Playback SearchAlarm List search playback HDD2Date/Time Search Playback Pause Copy Data ExportStill Image Copy Copy to Movie File MenuDisplay AlarmExport Event LOG List CallCall / Matrix monitors Main Monitor Mode Display ZoomMonitor Views / Operation Call / Matrix Monitors SequenceInstallation example 2 remote operators, 1 Edsr 900, 1 Edsr Remote Control11.1 RS-485 Remote Control RJ45 RS -485 pin assignmentWiring diagram multiple keyboard control IR Remote Controller optional With EDSR-1600 recorderView From Internet/Intranet Main Screen View From Internet/Intranet View From Internet/Intranet RUN PresetPTZ Camera Operation Password ProtectionUser Rights Specifications Appendix-APicture Quality KB ? When Recording with 160GB HDDNtsc Basic Standard High SuperiorUnit Hour System storageGB Recording ? When Recording with 320GB HDDAppendix-B Transmission setting Appendix C Serial Interface SpecificationsPin assignment of the D-SUB 9-pin connector RS-232 pin assignmentRemote Control Protocol Sample control code packetsFormat of message packet is as follows Length ByteReceiver ID Remote keys OPcode=0x4B Opcode Byte & Data bytesOPcode Matrix command OPcode=0x4D Checksum ByteDVR Alarm I/O pin assignmentAppendix-D EverFocus