MENU
(3)PRE-ALARM RECORD: (with Alarm In and Motion)
OP (Operation): Select ON to activate or OFF to deactivate
(4)PERMANENT RECORDING:
This recording mode is used for continuous recording in the quality of NORMAL RECORD settings.
Permanent record option: Operation: ON or OFF
Speed : 0.01 IPS, 0.3 IPS, 0.5 IPS, 1 IPS, 5 IPS, 10 IPS, 15 IPS, 20 IPS, 30 IPS, and 60 IPS.
IMPORTANT NOTE:
This mode is recommended in combination with alarm records (alarm contacts or motion alarm). If only alarm recording is active, the hard disk capacity is not used optimal because every alarm record opens a new segment on the hard disk. Depending on the alarm settings (duration, quality), this segment is not used totally and results in the total EDSR recording time being less than expected.
By activating a NORMAL or PERMANENT recording with low recording rate - from version 1.08 the EDSR900/1600 also supports 0,01 IPS (1 picture every 100 seconds)
When device had been set to be “PERMANENT” recording, and the device will follow “PERMANENT” setting when Rec bottom not been pushed(Device power on). If users push the Rec bottom, and it is “Normal” recording type.
Turn the JOG dial clockwise or
Press ENTER key to confirm the option and move to next column.
ENTER
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU
21