EverFocus EDSR-1600, EDSR-900 11.1 RS-485 Remote Control, RJ45 RS -485 pin assignment

Page 49

REMOTE CONTROL / OPERATION

11. REMOTE CONTROL

11.1 RS-485 REMOTE CONTROL

The new standard EverFocus EDSR remote control protocol allows sophisticated installations with DVR remote control at different installation sites.

EDSR remote control is supported by the keyboards KS KBJ (with 3-axis joystick and 2 additional RS-485 ports for telemetry control with independent telemetry protocols) and KS KBK (no telemetry). Up to 32 units are allowed in the RS -485 bus. The RS -485 bus requires serial wiring with 2-wire shielded twisted pair cable (“daisy chain”). Maximum cable length of the bus is 1200 m.

Star wiring is only possible with additional RS -485 distributor. Mixed installation is possible with following recorder types: EDSR 100 M, EDSR 400 M, EDSR 600, EDSR 900, EDSR 1600

For installation details, please refer to the KS-KBK and KS-KBJ keyboard manuals.

Installation example (2 remote operators, 1 EDSR 900, 1 EDSR 1600) :

 

MAIN1

M1-1

M1-2

M1-3 M1-4

Video 1 x

 

 

 

 

 

 

 

 

 

 

Video 5 x

 

 

 

 

 

Video 5 x

 

 

 

 

 

Video 1 x

CALL 1 CALL 2

MAIN2

M2-1

M2-2

M2-3 M2-4

 

DVR1: EDSR1600

RS-485 2 wire

DVR2: EDSR900

RS-485 2 wire

 

RS-485 2 wire

Operator 1:

1x Full screen view DVR1

1x Full screen view DVR2

Operator 2:

1x Multi screen view DVR1 (MAIN)

4x Full screen view DVR1 (MATRIX)

1x Multi screen view DVR1 (MAIN)

4x Full screen view DVR2 (MATRIX)

RJ45 (RS -485) pin assignment

There are two RJ-45 (RS-485) connectors on the back panel of the DVR (loop-through). For application, please refer to the following pin assignment.

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN

FUNCTION

1

2

3 4

5

6

 

7

8

 

 

 

 

 

 

 

1

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

RX +

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

RX -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44

Image 49
Contents V1.09 EDSR-1600Safety Precautions Power Disconnect Important Safeguards Important SafeguardsTable of Contents Product Overview Main FeaturesProduct Overview Specifications SpecificationsBack Panel Connections Back Panel ConnectionsON/OFF AC100~240VAlarm I/O Refer pin assignment in Appendix-C, System Connection Before InstallationSystem Connection Front Panel Keypads Front Panel KeypadsShuttle Ring and JOG Dial Chanel KeysIR Remote Controller receiver Operation Press Menu key to enter SET UP MenuOperation Insert a HDD IDE for Video StorageMenu Flow Menu flowMatrix CLOCK/LANGUAGE Setting Menu , we define Clock Setting MenuMenu Language English First SUN October Change Daylight Saving TimeWrong Timer Setting MenuCorrect Sequence Setting MENU, we define for Main Monitor Sequence Setting MenuTitle Setting Menu we define Title Setting MenuCovert Setting Menu we define Covert Setting MenuDefault setting is OFF for all cameras Alarm Recording MENU, we define Alarm Record Setting MenuMotion Record Setting Menu we define Motion Setting MenuOP Operation Default OFF HIT 1-9/16 to Manual Edit Record Setting Menu Permanent Recording PRE-ALARM Record with Alarm In and MotionPermanent record option Operation on or OFF Important NoteNetwork Setting MENU, we define Network Setting MenuAdmin USER-NAME Password LevelGeneral GuestControl Setting MENU, we define Control Setting MenuBuzzer Setting Menu Picture Size Archive Setting MenuTime Stamp Water MarkDialog Matrix Setting MenuCH, DWELL, Event Disk Menu PTZ Setting Menu PTZ Setting MenuExample Connection ED-2250 Dome to EDSR600/900/1600 Pelco D DIP switch 501 at ED2250RS-485 Connection ED-2250 dome RS-232 Connection ED2250 Dome System Setting MENU, we define System Setting MenuPlay with Audio AUDIO-1, AUDIO-2 Recording Alarm RecordingInstant Recording Permanent Recording Timer RecordingNormal Playback Playing BackPlay EnterSearch Playback Search PlaybackSegment List search playback SearchHDD2 Alarm List search playbackDate/Time Search Playback Still Image Copy Data ExportPause Copy Menu Copy to Movie FileExport Event LOG List AlarmDisplay CallMonitor Views / Operation Main Monitor Mode Display ZoomCall / Matrix monitors Sequence Call / Matrix Monitors11.1 RS-485 Remote Control Remote ControlInstallation example 2 remote operators, 1 Edsr 900, 1 Edsr RJ45 RS -485 pin assignmentWiring diagram multiple keyboard control With EDSR-1600 recorder IR Remote Controller optionalView From Internet/Intranet Main Screen View From Internet/Intranet View From Internet/Intranet PTZ Camera PresetRUN User Rights Password ProtectionOperation Appendix-A SpecificationsNtsc ? When Recording with 160GB HDDPicture Quality KB Basic Standard High SuperiorAppendix-B ? When Recording with 320GB HDDUnit Hour System storageGB Recording Pin assignment of the D-SUB 9-pin connector Appendix C Serial Interface SpecificationsTransmission setting RS-232 pin assignmentSample control code packets Remote Control ProtocolLength Byte Format of message packet is as followsReceiver ID OPcode Opcode Byte & Data bytesRemote keys OPcode=0x4B Checksum Byte Matrix command OPcode=0x4DAppendix-D Alarm I/O pin assignmentDVR EverFocus
Related manuals