MENU

6.8 RS232/RS485 SETTING MENU

RS232/RS485 SETTING MENU

RS232/RS485

: RS232

RS232/RS485 ID

: 01

BAUD RATE

: 9600

PARITY

: NONE

DATA BIT

: 8

STOP BIT

: 2

In the RS232/RS485 SETTING MENU, we define

(1)RS232/RS485: Choose RS232 or RS485 for activated.

(2)RS232/RS485 ID: This entry is used to assign each device with its own ID code, when more than on unit is used in one system through RS232/RS485.

There are two ID code for the Digital video recorder : 001 or 002

(3)BAUD RATE: There are 6 different speeds that can be used to transmit instruction or

information through the RS232/RS485 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud, 19200 baud,and 3840 baud. The default setting from the factory is 9600 baud.

(4)PARITY: Select parity lever: NONE/ODE/EVEN

(5)DATA BIT: Select data bit : 8 or 7

(6)STOP BIT: Select stop bit: 1 or 2

Left/Right Button: Press

Up/Down Button: Press

or or

to move the cursor to the left or right to change the value.

27

Image 33
Contents EDSR100H Safety Precautions Safety Warning AC100V~240V Power Cords Important Safeguards Important SafeguardsTable of Contents Product Overview Product Overview and FeaturesSpecifications Front Panel Keypads Front Panel KeypadsLeft/Right Button Press Up/Down Button Press Jog and Shuttle Dial Display Press this key to switch ON/OFFBack Panel Connections PowerBack Panel Connections AudioAlarm Input/ Output MonitorVideo in /Output RS232 System Connection System ConnectionOne Camera Connection Main Monitor Multiplexer VCR Out Multiplexer ConnectionMultiplexer VCR Multiplexer Main Monitor OutputMain Monitor Quad VCR Out Quad Connection. Quad with VCR in VCR out connectorQuad VCR Quad Main Monitor OutMain Monitor Quad Video Out to Video Recorder Quad connection. Quad without VCR in VCR out connectorInstallation Menu Version 1.0 2003/05/26 CLOCK/LANGUAGE Setting Menu , we SET CLOCK/ Language Setting MenuDate 2003/04/24 TUE Time Menu Language EnglishFrom 0000 to Daylight Setting Menu , we define Daylight Setting MenuFrom 0000 to END on JAN 1ST MONTimer Setting Menu Week Start Stop Speed Quality SET SUN Timer Setting MenuStandard OFF SUN Standard OFFSET SpeedNormal Recording MENU, we define Normal Record Setting MenuDisk Full MultiplexerAlarm Record Setting Menu Alarm Operation Recording Speed Alarm Record Setting MenuPRE-ALARM Operation Recording Speed Recording QualityAlarm Reset Type PRE-ALARM OperationPRE Alarm Time 15Figure 1 Alarm out Normally open connection use pin # 13 and #Normally Closed Connection use pin # 13 and # Alarm in and alarm reset AlarmAlarm CircuitRecord Buzzer Setting MenuArchive Setting Menu Picture Size Archive Setting Menu720x576 Time StampRS232/RS485 Setting Menu Baud RateParity None Data BIT Stop BIT System Setting Menu Play with Audio Password Enable System Setting MenuPassword OFFPress Yes to Renew HDD and Press Enter key to Exit Press no to renew HDD and Press Enter key to ExitCF Renew Instant Recording RecordingPress Record key to start the recording immediately REC StopPress Menu key and turn the jog dial to select the Alarm Alarm RecordingRecording Setting Menu Recording Operation MenuNormal Playback Playing BackPlay REV.PLAYSlow Forward/Reverse Playback PauseFrame/Field advance Forward/Reverse Search Playback Segment Search PlaybackSearch Alarm Search Playback Date/Time Search Playback Still Image Copy CopyPress the Play key to start playing back Press the Pause key to freeze the pictureCopy to Movie File Press Copy key and then the copy menu appearsCopy Copy to Movie File Pause Search Stop SUB 9-pin connector specifications Interface SpecificationsTransmission setting Pin assignment of the 9-pin D-SUB connectorRemote Control Protocol Receiver ID Digital Video Recorder Page Remote Controller Remote ControllerAppendix-A APPENDIX- A/Time Lapse Mode Recording TimeWhen Recording with 160-GB HDD APPENDIX-B/SECURITY Lock Setting Appendix-BLock USA Office Head OfficeJapan Office Beijing Office