Fasten the transfer box on the back panel of DVR with two screws
Pull out 6 connection terminals of the transfer box, corresponding connection marks can be clearly noticed. Connect function line according to connection marks
Loosen the screws on the connection terminal;connection diagram
Insert lines needed to corresponding terminals connection diagram
Fasten the screws on the terminals after insertion of the lines.(connection diagram
connection diagram
connection diagram
connection diagram
Notes:
a) “Ground”ground line | terminal |
|
|
| |
b)“+12v”provide the power to alarm device |
|
|
with current less than 2A |
|
|
c)“OUT 12” is two alarm outputs switch. |
|
|
Nomal open type |
|
|
d)485 AB is communication connection, |
|
|
used to connect such recorder control device |
|
|
such as control decoder |
|
|
e)+12C” is control power output, is used for |
| screw |
standby power for smoke sensor alarm device.. |
| |
|
| |
dismiss of the alarm needs the device to turn off |
|
|
the power. |
|
|
f)ALARMIN 1…8 is alarm input. High level voltage input. Input |
| |
voltage is |
|
|
10-Pin connection for DVR1604RW
If you want to control
62 | ! |