HCD-C5
SECTION 4
TEST MODE
[Factory Preset Mode]
∗This mode clears all data including preset data stored in the RAM to initial conditions. Excute this mode when returning the set to the customer.
Procedure:
1.Press the ?/1 button to turn the power on.
2.Press the FUNCTION z button to set the CD function. (except the TUNER function)
3.Press three buttons VOL + , CD Z and MD Z simultaneously.
4.The message “COLD RESET” blinks and the present contents are reset to the default values.
[Version and Destination Display Mode]
∗The version or destination is displayed.
Procedure:
1.Press the ?/1 button to turn the power on.
2.To enter the test mode, press the three buttons VOL + , x and MD Z simultaneously.
3.The model and destination are displayed.
4.Press the REC/REC IT/NORMAL and u buttons simul- taneously.
5.The version is displayed as “STR/CD V . ”.
6.Press the REC/REC IT/NORMAL and u buttons simul- taneously.
7.The version is displayed as “MD V . ”.
8.Press the REC/REC IT/NORMAL and u buttons simul- taneously, then the mode returns to step 3.
9.To exit from this mode, press the ?/1 button to turn the power off.
[FL Tube Test Mode]
∗All fluorecent segments and LEDs are tested.
Procedure:
1.Press the ?/1 button to turn the power on.
2.To enter the test mode, press three buttons VOL + , x and
./m TUNING - simultaneously.
3.All segments and LEDs are turned on.
4.Press the REC/REC IT/NORMAL and u buttons simul- taneously.
5.All segments are turned off (All LEDs still lit).
6.Press the REC/REC IT/NORMAL and u buttons simul- taneously.
7.Almost half segments are turned on. (PATTERN 1)
8.Press the REC/REC IT/NORMAL and u buttons simul- taneously.
9.The segments which are turned on in step 7 are turned off, then remaining segments are turned on. (PATTERN 2)
10.Press the REC/REC IT/NORMAL and u buttons simul- taneously, the mode returms to step 3 and all segments are turned on.
11.To exit from this mode, press the ?/1 button to turn the power off.
[Key Test Mode]
∗Keyboard check.
Procedure:
1.Press the ?/1 button to turn the power on.
2.To enter the test mode, press three buttons VOL + , x and >/M TUNING + simultaneously.
3.In the key test mode, the fluorecent indicator displays “KEY00”.
4.Each time a button is pressed, “KEY ” value increases. However, once a button is pressed, it is no longer taken into account.
5.To exit from this mode, press three buttons simultaneously as step 2 , or disconnect the power cord.
[Amp Test Mode]
Procedure:
1.Press the ?/1 button to turn the power on.
2.Press three buttons VOL
3.Press two buttons REC/REC IT/NORMAL and x simulta- neously.
4.The message “7 [TESTMIN]” is displayed for a few seconds.
5.Press two buttons REC/REC IT/NORMAL and x simulta- neously again.
6.Each time two buttons are depressed, the display changes as “8 [TESTMID]” , “9 [TESTMAX]”, and “10 [TESTSUR]” .
7.Press the VOL + button, the display changes “VOLUME 21” to “VOLUME MAX”.
8.Press the VOL - button, the display changes “VOLUME 21” to “VOLUME MIN”.
9.To exit from this mode, press the ?/1 button to turn the power off and cold reset is executed.
[CD Test Mode]
∗The CD system versions are displayed.
Procedure:
1.Press the ?/1 button to turn the power on.
2.Press the FUNCTION z button to set the CD function.
3.Press three buttons of VOL + , x and CD SYNC HIGH simultaneusly.
4.The message “dut CD VER” is displayed.
5.Press the CD Z button and the version “CD . ” is dis- played.
6.Press the >/M TUNING + button and “CDSYS ” is displayed.
7.Each time the >/M TUNING + button is depressed , the display changes as “CDMA S”, “CDBD O”, “CDCD M”.
8.By depressing the ./m TUNING - button the versions are displayed in reverse.
9.To exit this mode, press the ?/1 button to turn the power off.
24