HCD-C5
5-1. Operating the Continuous Playback Mode
1. Entering the continuous playback mode
(1)Set the disc in the unit. (Whichever recordable discs or discs for playback only are available)
(2)Press the . “R” or > “R” button to display “CPLAY1MODE” (C34).
(3)Press the ENTER/YES “R” button to change the display to “CPLAY1MID”.
(4)When access completes, the display changes to “C = AD = )”.
Note: The numbers “” displayed show you error rates and ADER.
2. Changing the parts to be played back
(1)Press the ENTER/YES “R” button during continuous play- back to change the display as below.
“CPLAY1MID” t “CPLAY1OUT” t “CPLAY1IN”
When pressed another time, the parts to be played back can be moved.
(2)When access completes, the display changes to “C = AD = )”.
Note: The numbers “ ” displayed show you error rates and ADER.
3. Ending the continuous playback mode
(1)Press the MENU/NO “R” button. The display will change to “CPLAY1MODE” (C34).
(2)Press the MD Z button and take out the disc.
Note: The playback start addresses for IN, MID, and OUT are as follows.
IN | : 40h cluster |
MID | : 300h cluster |
OUT | : 700h cluster |
1. Entering the continuous recording mode
(1)Set a recordable disc in the unit.
(2)Press the . “R” or > “R” button to display “CREC 1MODE” (C35).
(3)Press the ENTER/YES “R” button to change the display to “CREC 1MID”.
(4)When access completes, the display changes to “CREC 1(
)” and “ REC ” is displayed.
Note: The numbers “” displayed shows you the recording posi- tion addresses.
2. Changing the parts to be recorded
(1)When the ENTER/YES “R” button is pressed during con- tinuous recording, the display changes as below.
“CREC 1MID” t “CREC 1OUT” t “CREC 1IN”
When pressed another time, the parts to be recorded can be changed. “ REC ” goes off.
(2)When access completes, the display changes to “CREC 1(
)” and “ REC ” is displayed.
Note: The numbers “ ” displayed shows you the recording posi- tion addresses.
3. Ending the continuous recording mode
(1)Press the MENU/NO “R” button. The display changes to “CREC 1MODE” (C35) and “ REC ” goes off.
(2)Press the MD Z button and take out the disc.
Note 1: The recording start addresses for IN, MID, and OUT are as follows.
IN : 40h cluster
MID : 300h cluster
OUT : 700h cluster
Note 2: The MENU/NO “R” button can be used to stop recording anytime.
Note 3: Do not perform continuous recording for long periods of time above 5 minutes.
Note 4: During continuous recording, be careful not to apply vi- bration.
27