HCD-C5
Procedure:
1.Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin 6 (VC) on the BD (MD) board.
2.Load a disc (any available on the market). (Refer to Note 1)
3.Press the M “R” button to move the optical
4.Press the . “R” or > “R” button to display “EF MO ADJUST” (C07).
5.Press the ENTER/YES “R” button to display “EFB = MO- R”. (Laser power READ power/Focus servo ON/tracking servo OFF/spindle (S) servo ON)
6.Press the .“R” or >“R” button so that the waveform of the oscilloscope becomes the specified value.
(When the . “R” or > “R” button is pressed, the of “EFB= ” changes and the waveform changes) In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.
(Read power traverse adjustment)
Traverse Waveform
A
VC
B
Specification A = B
7.Press the ENTER/YES “R” button and save the result of
adjustment to the
will be displayed for a moment. Then “EFB =
8.Press the .“R” or >“R” button so that the waveform of the oscilloscope becomes the specified value.
(When the . “R” or >“R” button is pressed, the of
“EFB= ” changes and the waveform changes) In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible. (Write power traverse adjustment)
Traverse Waveform
A
VC
B
Specification A = B
9.Press the ENTER/YES “R” button, and save the adjustment
results in the
10.“EFB =
The optical
11.Press the . “R” or >“R” button until the waveform of the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.
Traverse Waveform
A
VC
B
Specification A = B
12.Press the ENTER/YES “R” button, and save the adjustment
results in the
Next “EF MO ADJUST” (C07) is displayed. The disc stops rotating automatically.
13.Press the MD Z button and take out the disc.
14.Load the check disc
15.Press the . “R” or > “R” button to display “EF CD ADJUST” (C08).
16.Press the ENTER/YES “R” button to display “EFB = CD”. Servo is imposed automatically.
17.Press the .“R” or >“R” button so that the waveform of the oscilloscope moves closer to the specified value.
In this adjustment, waveform varies at intervals of approx. 2%. Adjust the waveform so that the specified value is satisfied as much as possible.
Traverse Waveform
A
VC
B
Specification A = B
18.Press the ENTER/YES “R” button, display “EFB = SAVE” for a moment and save the adjustment results in the
Next “EF CD ADJUST” (C08) will be displayed.
19.Press the MD Z button and take out the check disc.
Adjustment Location: BD (MD) board (see page 44)
42