HCD-C5
16. AUTO GAIN CONTROL OUTPUT LEVEL ADJUSTMENT
Be sure to perform this adjustment when the optical
If the adjustment results becomes “Adjust NG!”, the optical
16-1. CD Auto Gain Control Output Level Adjustment
Procedure:
1.Load the check disc
2.Press the . m “R” or M > “R” button to display “AG Set (CD)” (C11).
3.When the ENTER/YES “R” button is pressed, the adjustment will be performed automatically.
“Complete!” will then be displayed momentarily when the value is recorded in the
4.Press the MD Z button and take out the check disc.
16-2. MO Auto Gain Control Output Level Adjustment
Procedure:
1.Load the test disc
2.Press the . “R” or > “R” button to display “AG Set (MO)” (C10).
3.When the ENTER/YES “R” button is pressed, the adjustment will be performed automatically.
“Complete!” will then be displayed momentarily when the value is recorded in the
4.Press the MD Z button and take out the test disc.
Adjustment and checking Loacation:
– BD (MD) BOARD (Component Side) – | – BD (MD) BOARD (Conductor Side) – |
D101
IC101
|
|
| CN105 | 1. I+3V | |
CN101 | |||||
1 |
2. IOP
| 7 | 3. GND |
|
| |
|
| 4. TE |
|
| 5. FE |
|
| 6. VC |
IC151 |
| 7. RF |
|
| |
IC190 |
|
|
Note: It is useful to use the jig for checking the waveform. (Refer to Servicing Notes on page 6)