HCD-C5
6-4. Auto Check
This test mode performs CREC and CPLAY automatically for mainly checking the characteristics of the optical
Procedure:
1.Press the .“R” or >“R” button to display “AUTO CHECK” (C01).
2.Press the ENTER/YES “R” button. If “LDPWR ” is displayed, it means that the laser power check has not been performed. In this case, perform the laser power check and Iop Compare, and then repeat from enter the MD test mode.
3.If a disc is in the mechanical deck, it will be ejected forcibly. “DISC IN” will be displayed in this case. Load a test disc (MDW-
4.If a disc is loaded at step 3, the check will start automatically.
5.When “XX CHECK” is displayed, the item corresponding to XX will be performed.
When “06 CHECK” completes, the disc loaded at step 3 will be ejected. “DISC IN” will be displayed. Load the check disc
6.When the disc is loaded in the step 5, the check will automatically be resumed from “07 CHECK”.
7.After completing to test item 12 (“oC CHECK”), check OK or NG will be displayed. If all items are OK, “CHK ALL OK” will be displayed. If any item is NG, it will be displayed as “NG:xxxx”.
When “CHK ALL OK” is displayed, it means that the optical pick- up is normal. Check the operations of other parts (spindle motor, sled motor, etc.).
When displayed as “NG:xxxx”, it means that the optical
6-5. Other Checks
All the following checks are performed by the Auto Check mode. They therefore need not be performed in normal operation.
6-6. Traverse Check
Note 1: Data will be erased during MO reading if a recorded disc is used in this adjustment.
Note 2: If the traverse waveform is not clear, connect the oscilloscope as shown in the following figure so that it can be seen more clearly.
oscilloscope (DC range)
BD (MD) board | 330 k Ω | |
| ||
CN105 pin 4 (TE) | + | |
CN105 pin 6 (VC) | – | |
10 pF | ||
|
Connection:
oscilloscope (DC range)
BD (MD) board
CN105 pin 4 (TE) |
|
| + | V: 0.1 V/div |
|
| |||
CN105 pin 6 (VC) |
|
| – | |
|
| H: 10 ms/div |
Procedure:
1.Connect an oscilloscope to CN105 pin 4 (TE) and CN105 pin 6 (VC) on the BD (MD) board.
2.Load a disc (any available on the market). (Refer to Note 1)
3.Press the M “R” button to move the optical
4.Press the . “R” or > “R” button to display “EF MO CHECK”(C14).
5.Press the ENTER/YES “R” button to display “EFB = MO- R”. (Laser power READ power/Focus servo ON/tracking servo OFF/spindle (S) servo ON)
6.Observe the waveform of the oscilloscope, and check that the
specified value is satisfied. Do not press the . “R” or
>“R” button.
(Read power traverse checking)
Traverse Waveform
A
VC
B
Specified value : Below 10% offset value
Offset value (%) = IA – BI X 100 2 (A + B)
7.Press the ENTER/YES “R” button to display “EFB = MO- W”.
8.Observe the waveform of the oscilloscope, and check that the specified value is satisfied. Do not press the . “R” or
>“R” button. (Write power traverse checking)
Traverse Waveform
A
VC
B
Specified value : Below 10% offset value
Offset value (%) = IA – BI X 100 2 (A + B)
38