SLR • SLC • SLD OPERATOR INSTALLATION GUIDE
IMPORTANT NOTES FOR INSTALLATION OF
MASTER/SLAVE APPLICATIONS
When setting up Master/Slave gate operators, it is best to make adjustments and run each operator individually. To do this, simply:
a.Set Dip Switch #4 to proper hand of operation
b.Set Dip Switch #8 as Master (off)
Run each operator making current sensing adjustments as necessary, as indicated on the Control Board Adjustments page of this installation guide. When both operators have been adjusted, turn power off, then turn on Dip Switch #8 in the operator chosen as the Slave.
The timer to close and radio/single button behavior are set in the Master operator.
The following selections are set individually: Current Sensing
Maximum Run Timer
SURGE PROTECTOR INSTRUCTIONS
The optional surge protector should be connected to any inputs that have an accessory connected to it. This includes the
Do not simply unhook the shorted wire, as this removes the protection from the circuit that was saved by the protector in the first place!