Cosco SLR, SLD Gate Operator Classifications, Safety Information, PRE-INSTALLATION Information

Page 3

SLR • SLC • SLD OPERATOR INSTALLATION GUIDE

GATE OPERATOR

CLASSIFICATIONS

All gate operators can be divided into one of four different classifications, depending on their design and usage.

Class I: Residential

A vehicular gate operator (or system) intended for use in a home of one to four single-family dwellings, or a garage or parking area associated therewith.

Class II: Commercial or General Public Access

A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family hous- ing unit (five or more single-family units), hotel, garage, re- tail store, or other building servicing the general public.

Class III: Industrial or Limited Access

A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the gen- eral public.

Class IV: Restricted Access

A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not ser- vicing the general public, in which unauthorized access is prevented via supervision by security personnel.

IMPORTANT!!

Before installing the gate operator, make sure the gate slides free and level throughout the entire opening distance. If the gate does not seem to operate properly, it may affect the op- erator performance or greatly shorten the life of the unit. The gate should be designed so that airflow through the fabric is ample to prevent wind resistance and drag.

SAFETY INFORMATION

AND WARNINGS

Read the following before beginning to install OSCO slide gate operators:

1.Read the yellow “Safety Instructions” brochure enclosed with the packet of information. If you do not have one, please call OSCO at 1-800-333-1717 to request one. Read and follow all instructions.

2.All electrical connections to the power supply must be made by a licensed electrician and must observe all national and local electrical codes.

3.A separate power-disconnect switch should be located near the operator so that primary power can be turned off when necessary.

4.Install the enclosed warning signs on both sides of the gate. Each sign must be plainly visible from the side of the gate on which they are mounted.

5.Never reach between, through or around the fence to operate the gate.

6.You must install all required safety equipment.

PRE-INSTALLATION INFORMATION

Before unpacking, inspect the carton for exterior damage. If you find damage, advise the delivery carrier of a potential claim.

Inspect your package carefully. For your convenience, you can check your accessory box parts with the enclosed pack- ing slip. Claims for shortages will be honored for only 30 days from the date of shipment.

Before installing the operator, read this manual completely to ensure all requirements for proper installation are present. Verify that the voltage to be used matches the voltage of the operator.

The following contact or non-contact obstruction detection devices have been approved for use with OSCO slide gate operators as part of a UL325 compliant installation:

Contact Edges:

Miller Models*: MG0-20, MGR-20, MGS-20, and ME-120

Photoeyes:

2520-441 MMTC Model IR-55 photoeye, 165’ with mounting hardware

2520-031 MMTC Model E3K photoeye, 28’ with mounting hardware

*for OSCO part numbers, contact a sales representative for details

- 3 -

10-05-9

Image 3
Contents SLR SLC SLD Table of Contents SLR SLC SLD Operator Installation GuideSafety Information PRE-INSTALLATION InformationGate Operator Classifications Wiring Specifications USE Copper Wire onlyPAD Mounting Instructions for Models SLR, SLC & SLDGate Bracket and Chain Assembly Instructions Models SLR, SLC and SLD Optional Vent Plug InstallationOptional Torque Limiter Adjustments To adjust the torque limiter in models SLR, SLC and SLDLimit NUT Adjustments Electrical Connection and AdjustmentsControl Board Adjustments Dip SwitchesBoard Control With Motor Close Terminal Connection DescriptionsMulti-turn Potentiometer Current Sensing AdjustmentsClose Direction Current Sense Adjustment Open Direction Current Sense AdjustmentOnboard L.E.D. Indicator Descriptions Surge Protector Instructions Important Notes for Installation MASTER/SLAVE ApplicationsCharger Board Sleep Mode Control and Accessory Connection Illustrations SLR SLC SLD Operator Installation Guide SLR SLC SLD Operator Installation Guide AC Models only Loop Layout Illustration Edge Layout Illustration #1 Edge Layout Illustration #2 Photo EYE Illustration Picket Gate Illustration Track Gate Illustration Operator fails to start TroubleshootingModel SLR Mechanical Parts Exploded View Description Model SLR Mechanical Parts ListModel SLC Mechanical Parts Exploded View Description Model SLC Mechanical Parts ListModels SLR SLC Control BOX Parts List Model SLD Mechanical Parts Exploded View Model SLD Mechanical Parts List Model SLD Control BOX Parts List Brush Replacement Battery MaintenanceMaterial Safety Data Sheet Mobil SHC Imperial Oil SLR SLC SLD Operator Installation Guide General Preventative MaintenanceThis page intentionally left blank Gate Operator Installation Checklist