Allstar Products Group ANSI/UL 325 Starting the Operator Final Settings, PRE Running Checklist

Page 22

D: STARTING THE OPERATOR - FINAL SETTINGS

WARNING!

RISK OF ENTRAPMENT

OVERLOAD SENSITIVITY HAS NOT BEEN SET. DO NOT ALLOW ANYONE NEAR THE GATE AND DO NOT LEAVE GATE AND GS4000 UNATTENDED UNTIL FOLLOWING PROCEDURES HAVE BEEN COMPLETED.

USE CAUTION DURING THIS FINAL

ADJUSTMENT PERIOD.

PRE RUNNING CHECKLIST

Before running the GS4000, make sure:

1.The proper Left-or Right-hand or Bi-Parting wiring has been completed (if applicable).

2.The Limit Switch Cams have been preliminarily set.

3.The Overload Sensitivity has been preset.

4.The Switch Selectable Options have been set.

5.The Gate has been positioned in the center of it's travel.

6.The Torque Limiter is properly adjusted.

7.No other devices should be connected to the terminal strip until the powering-up procedures are completed.

RUNNING THE GS4000

Turn ON the main power switch. The Power Lamp will come on. The Alarm will sound for 1/2 second (a brief chirp), the Alarm indicator lamp will flash for 1/2 second. The gate should not move. If the gate moves in either direction turn off the power and call Factory Service for assistance.

1.Give the GS4000 a command to open by connecting the jumper wire from Terminal #16 (COMMON) to Terminal #6 (OPEN). The gate should move to the fully open position.

2.If the TIMER TO CLOSE option has been selected, the timer will activate the gate to close within a maximum of 60 seconds depending on the setting of the TIMER TO CLOSE potentiometer (See Figure 23, Page 20).

3.If the TIMER TO CLOSE is not to be used on this installation, activate the gate to Close by connecting the jumper wire from Terminal #16 (COMMON) to Terminal #7 (CLOSE). The gate should move to the fully closed position.

4.Allow the gate to close and note the position of the gate.

IF THE GATE HITS THE OPEN OR CLOSE STOPS OR EITHER THE MOTOR OPEN OR CLOSE LIGHT REMAINS ON AFTER REACHING THE MECHANICAL STOPS AND THE LIMIT SWITCH LIGHT IS "ON", TURN OFF THE

MAIN POWER SWITCH. IF THE GATE HITS THE MECHANICAL LIMIT AND THE LIMIT SWITCH LIGHT DOES NOT COME ON, THE LIMIT CAM OR THE STOP WILL NEED TO BE READJUSTED.

If the gate stops short of the desired fully open or closed position or if it bangs against the end stops, TURN OFF THE MAIN POWER and reset the appropriate Limit Switch Cam. After you have attained the final adjustment, run the GS4000 open and closed several times to ensure that the positions set will be retained.

SMART™ SETTING - MAXIMUM RUN TIMER

The GS4000 is equipped with a Self adjusting MAximum Run Timer, SMART™ , that will turn the GS4000 OFF if a Limit Switch command is not received within five seconds of the time required to fully Open or Close the gate. The purpose of the Maximum Run Timer is to turn off the GS4000 if the gate should become jammed when opening or closing. In this case, the Limit Switch will not be activated. Should this occur, the Torque Limiter will slip and the pads will be worn out prematurely. The Maximum Run Timer will prevent this by turning OFF the GS4000. Once the obstruction is removed, any command will reactive the GS4000.

To set the Smart™ Maximum Run Time fully open and close the gate five (5) times. The control board will sense the time required and add approximately four seconds.

WHEN CHECKING OPERATION OF THE LIMIT SWITCHES, BE CERTAIN THE MOTOR IS BEING TURNED OFF BY THE LIMIT SWITCH AND NOT THE MAXIMUM RUN TIMER. SHOULD THE GATE REACH THE OPEN OR CLOSED POSITION AND THE RESPECTIVE LIMIT SWITCH LIGHT DOES NOT COME ON BUT THE MOTOR STOPS RUNNING, THEN THE MAXIMUM RUN TIMER IS TURNING OFF THE MOTOR. TURNING THE GS4000 OFF BY THE MAXIMUM RUN TIMER WILL CAUSE THE TORQUE LIMITER TO SLIP FOR AN UNNECESSARY AMOUNT OF TIME EACH TIME THE GATE IS OPERATED. THE TORQUE LIMITER PADS ARE NOT CAPABLE OF LONG LIFE UNDER THESE CONDITIONS. PREMATURE WEAR WILL OCCUR AND FREQUENT ADJUSTMENT OF THE TORQUE LIMITER WILL BE NECESSARY.

FINAL SETTING OF THE CLOSE TIMER

To alter the amount of time that the close timer will hold the gate open, adjust the timer potentiometer located on the Control Board. See Figure 23, page 20.

The Close Timer is adjustable from 2 to approximately 60 seconds. Turning the potentiometer clockwise increases the delay; turning it counterclockwise decreases the delay.

22

Image 22
Contents Gate Star Table of Contents WA R N I N G H I G H V O LTA G EPRE-INSTALLATION Notes Connections for External Entrapment Prevention SensorsGate System Design and Installation Safety Check List Pinch Points Entrapment Zone Electric Gate EdgeMoving Gate Gate System Design InstallationAS the Installer YOU are Responsible for DeathConcrete PAD Preparing the SitePlacing the Vehicle Detector Loops Loop Diagrams Vehicle Detector Loop Blanking for Swing GatesOther Voltages and 3 Phase Systems Electrical Power RequirementsService Conduit Installing the Operator Tools RequiredInstalling the GS4000 ARM Placing the GS4000 Mechanical UnitInstalling the GS4000 Control BOX Electrical Hook UPRight Hand and Left Hand Installation Connecting the AC Wiring Volt InstallationsWiring the Mechanical Unit to the Control BOX Additional Lightning ProtectionAccessory Equipment HOOK-UP BI-PARTING WiringBi-Parting Installation Limit & Motor Wiring Diagram Four Wire Receivers Wiring Radio Receivers to the Terminal StripWiring a 3-BUTTON Station Wiring Vehicle Detectors Wiring a KEYPAD, Card Reader or Telephone Entry SystemConnecting the Vehicle Detector Vehicle Detector PowerPresetting the Motor Overload Sensitivity Potentiometers Connecting the Loop WiresShadow Loop SwitchClose Close PhotoNO-LOAD Test Mode Setting the Limit SwitchesSetting the Switch Selectable Options OPEN/CLOSE Push Button ENABLE/ Disable Patent no ,611,205Applying Power to the GS4000 Timer to Close SettingIndicator Lamps Smart Setting Maximum RUN Timer Starting the Operator Final SettingsPRE Running Checklist Final Setting of the Close TimerInstallation Notes for Auxiliary Equipment Final Setting of the Motor Overload SensitivityPrecautions for Pedestrian Traffic or Residential Areas To the Owner/End User of Allstar’s GS4000Entrapment Zone Basic Operational GuidePinch Points Entrapment Zone Mechanical Unit Exploded View GS4000 Mechanical Unit Exploded ViewMechanical Unit Parts List ARM KIT & Control BOX Exploded View & PartsTechnical Specifications Physical Drive

ANSI/UL 325 specifications

Allstar Products Group is a prominent manufacturer in the realm of access control and safety products, and its commitment to quality is evidenced by its compliance with ANSI/UL 325 standards. These standards are essential for ensuring the safety and reliability of automatic gates and their related components, focusing on minimizing risks associated with entrapment and injury.

One of the key features of Allstar's ANSI/UL 325 compliant products is their advanced safety mechanisms. These include integrated sensing technology that detects the presence of objects or obstacles in the path of the gate, effectively preventing accidents. This safety technology often encompasses features such as photo eyes and edge sensors that can immediately halt or reverse the movement of a gate if an obstruction is detected.

Additionally, Allstar’s product range is notable for its robust design and durability. Built to withstand various environmental conditions, these products use high-quality materials that ensure longevity and reliability, meeting the stringent demands of both residential and commercial applications. The designs are also forward-thinking, incorporating user-friendly features that allow for easy installation and maintenance.

Another characteristic that sets Allstar apart is their integration of advanced technologies. Many of their products support smart technology, enabling users to control their gates through mobile applications or remote access systems. This integration allows for convenience and enhanced security, providing real-time alerts and status updates.

Allstar Products Group also emphasizes compliance to facilitate peace of mind for users. All their ANSI/UL 325 certified products undergo rigorous testing procedures to ensure they meet the stringent safety and performance requirements set forth by the American National Standards Institute and Underwriters Laboratories. This adherence to such standards not only assures consumers of reliability but also aligns with the industry’s best practices.

In conclusion, Allstar Products Group’s ANSI/UL 325 compliant products exemplify cutting-edge safety features, robust construction, and advanced technology integration. Their commitment to quality and safety ensures that customers can enjoy the benefits of automatic gate systems with confidence, knowing that they adhere to the highest safety standards in the industry.