Pelco DD53TC16-X manual Scan Speed, Limit Stops

Page 24
SCAN SPEED

SPECTRA III

LANGUAGEENGLISH

<SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS>

ACK ALERT*

RESET CAMERA

CYCLE CAMERA POWER

REBOOT SYSTEM

EXIT

DOME SETTINGS

<CAMERA>

<MOTION> <POWER UP> <LINE SYNC> <PRESETS> <PATTERNS> <ZONES>

<TITLE TEXT> <ALERT>* <CLEAR> <PASSWORD>

BACK

EXIT

MOTION

AUTO FLIP

ON

PROPORTIONAL PAN

ON

PARK TIME (MINUTES)

0

PARK ACTION

NONE

SCAN SPEED (DEG/S)

25

LIMIT STOPS

ON

<SET MANUAL STOPS>

 

<CLEAR MANUAL STOPS>

 

<SET SCAN STOPS>

 

<CLEAR SCAN STOPS>

 

<SET AZIMUTH ZERO>

 

<CLEAR AZIMUTH ZERO>

 

BACK

 

EXIT

 

REFERENCE INFORMATION

 

MANUAL LIMITS SET

NO

SCAN LIMITS SET

NO

*This setting only applies to Pressurized Spectra III dome systems with software version 1.25 or higher.

SCAN SPEED

Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed is adjustable from 1 to 40 degrees per second through the programming menu. The default setting is 25 degrees per second.

LIMIT STOPS

Limit stops are programmable stops that limit the pan range of the dome. There must be two limits, a left and a right, to define an area.

There are two types of limit stops:

MANUAL

A manual (joystick) pan operation stops when a limit stop is

 

reached.

SCAN

The dome reverses direction during random, frame, or auto

 

scanning when a limit stop is reached.

To set manual or scan stops:

1.Use the joystick to position the cursor beside SET MANUAL STOPS or SET SCAN STOPS.

2.Press Iris Open.

3.Follow the directions displayed on the monitor.

NOTE: In order for the manual or scan stops to work, the LIMIT STOPS setting must be ON.

To clear manual or scan stops:

1.Use the joystick to position the cursor beside CLEAR MANUAL STOPS or CLEAR SCAN STOPS.

2.Press Iris Open.

3.Follow the directions displayed on the monitor.

24

C2446M-E (11/05)

Image 24
Contents Spectra III Series Models DD53TC16 & DD53TC16-XO P E R AT I O N / P R O G R A M M I N G C2446M-E11/05Page OPERATION/PROGRAMMING MANUAL MODELS DD53TC16 & DD53TC16-X16X LowLight COLOR TECHNOLOGY C2446M-E11/05 CONTENTS POWER UP WELCOME Getting StartedHOW TO OPERATE YOUR DOME SYSTEM How to ControlPresets AlarmsAccessing Main Menu Preset CM6700/CM6800KBD200A/KBD300A Direct Mode Only CM9500KBD4000/KBD4002 MPT9500NET300/NET350/NET4001A WS5050Preset Function QUICK START GUIDE - SYSTEM SETUPPresets Press Iris Close to cancel selectionC2446M-E11/05 LANGUAGE Quick Programming GuideSYSTEM INFORMATION DISPLAY SETUP Quick Programming GuideLabel Position DOME SETTINGS CameraAUTO FOCUS ZOOM LIMITAdvanced Camera Settings SHUTTER SPEEDAGC LIMIT AUTO IRIS Auto Iris LevelAuto Iris Peak Quick Programming GuideAUTO SHARPNESS AUTO WHITE BALANCEThere are two settings ON defaultBACKLIGHT COMPENSATION BLC VIDEO LEVELQuick Programming Guide Backlight compensation is not activatedMotion Settings AUTO FLIPPROPORTIONAL PAN PARK TIME Park ActionDome goes to preset Quick Programming GuideSCAN SPEED LIMIT STOPSAZIMUTH ZERO To program azimuth zero2.Press Iris Open 3.Follow the directions displayed on the monitorPower Up POWER UP ACTIONLine Sync Quick Programming GuidePresets PresetAction Patterns Quick Programming GuideZones Title Text Quick Programming GuideAlert REPEATSystem Condition Alert MessageRESET ALERT ACK ACTIONACTIVATE AUX CURRENT READINGClear ACK ALERT RESET CAMERA CYCLE CAMERA POWERREBOOT SYSTEM EXIT DOME SETTINGS CAMERA BACK EXIT CLEAR RESTORE FACTORY DEFAULTS BACKPassword Quick Programming GuideRESET, CYCLE POWER, REBOOT RESET CAMERACYCLE CAMERA POWER REBOOT SYSTEMSOFTWARE/LANGUAGE FILE UPLOAD UPLOAD ICONUpload Icon SPECIFICATIONS DD53TC16DD53TC16-X REGULATORY NOTICES RADIO AND TELEVISION INTERFERENCEREVISION HISTORY Page Page World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & CanadaTel 800/289-9100 Fax 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120