Page 7
Installation
FIGURE 5. MDR 26-Pin Connector (0226-622VC)
MDR 26-Pin Connector
(0226-622VC)
Pin# | Description | Pin# | Description |
|
|
|
|
1 | GND (shield) | 14 | GND (Shield) |
|
|
|
|
2 | X0- | 15 | X0+ |
|
|
|
|
3 | X1- | 16 | X1+ |
|
|
|
|
4 | X2- | 17 | X2+ |
|
|
|
|
5 | Xclk- | 18 | Xclk+ |
|
|
|
|
6 | X3- | 19 | X3+ |
|
|
|
|
7 | SerTC+ | 20 | SerTC- |
|
|
|
|
8 | SerTFG- | 21 | SerTFG+ |
|
|
|
|
9 | VINIT | 22 | VINIT (CC1+) |
|
|
|
|
10 | INTEG (CC2+) | 23 | INTEG |
|
|
|
|
11 | CC3- | 24 | CC3+ |
|
|
|
|
12 | CC4+ | 25 | CC4- |
|
|
|
|
13 | GND (shield) | 26 | GND (Shield) |
|
|
|
|
2.2.2Power Supply and Power Cable Setup
PULNiX recommends the following power supply:
1.2A power supply |
If you are providing power through the
•The lead ends must be twisted together and
•Use shrink tubing or a similar insulator to prevent exposed leads from touching.
•The +12V lead is marked with a red stripe or white lettering; be sure not to reverse the leads.
•All connections must be properly insulated to prevent shorting.
If using PULNiX power cables, such as the
FIGURE 6. 12P-02S Power Cable
|
| +12 V | |
| GND (Gray) |
|
|
Male | Power (Yellow) |
|
|
| Video Out (Red Coax) | } | |
| HD In (White Coax) |
| |
| VD In (Black Coax) |
|
Monitor
Frame Grabber