TABLE 2. RS-232C Control Commands Summary Table
1st CHAR | 2nd CHAR | |
“S” | (Shutter) | “M” (Manual) |
|
| “A” (Async) |
“G” | (Gain) | “M” (Main) |
|
| “A” (Fine A CH) |
|
| “B” (Fine B CH) |
“V” | (A/D Vref) | “A” (CH1) |
|
| “B” (CH2) |
|
| “T” (Top) |
|
| “L” (BTM/Vsub) |
“W” | (Write) | “P” (Page) |
|
| “U” (User) |
|
| “S” (System) |
“L” | (Load) | “P” (Page) |
|
| “U” (User) |
|
| “S” (System) |
“R” | (Report) | “R” (Current) |
|
| “P” (Page) |
|
| “U” (User) |
|
| “S” (System) |
|
| “X” (Execute) |
|
| “D” (Date) |
“C” | (Clock) | “0” (120Hz) |
|
| “1” (60Hz) |
“N” | (Partial Scan) | “0” (Normal) |
|
| “1” (200 lines) |
|
| “2” (100 lines) |
“O” | (Async sync out) | “0” (Continuous) |
|
| “1” (One Shot) |
3rd CHAR | Response | Functions |
“0” - “9” Mode | ACK | Manual shutter mode |
“0” - “8” Mode | ACK | Async shutter mode |
“9” (Pulse width) | ACK | Pulse width mode |
“00” - “FF” | ACK | Main CH Gain Control |
“00” - “FF” | ACK | CH1 Gain Fine Tuning |
“00” - “FF” | ACK | CH2 Gain Fine Tuning |
“00” - “FF” | ACK | CH1 Vref Fine Tuning |
“00” - “FF” | ACK | CH2 Vref Fine Tuning |
“00” - “FF” | ACK | Vtop voltage setting |
“00” - “FF” | ACK | Vbottom - Vsub setting |
“0” - “6” | ACK | Write to P EPROM |
“A” - “D” | ACK | Write to U EPROM |
“A” - “D” | ACK | Write to S EPROM |
“0” - “6” | ACK | Load from P EPROM |
“A” - “D” | ACK | Load from U EPROM |
“A” - “D” | ACK | Load from S EPROM |
| ACK | ACK + “RR”+12x2 bytes |
“0” - “6” | ACK | ACK + “P”+{“9” - “F”}+ 12x2 bytes |
“A” - “D” | ACK | ACK + “U”+{“9” - “F”}+ 5x2 bytes |
“A” - “D” | ACK | ACK + “S”+{“9” - “F”}+ 5x2 bytes |
| ACK | Set camera with loaded data |
| DATE | Report program date |
| ACK | Using master clock |
| ACK | Using half of master clock |
| ACK | Normal scan |
| ACK | 200 line scan |
|
| 100 line scan |
| ACK | Continuous sync out in Async Mode. |
|
| One sync with on VINIT. |