JAI TM-6710 operation manual Report from pages RP 0-6 command. Camera responds, Command C

Page 27

Page 21

Operation

1.Report from RAM “R R” command. Reads out the current setting. The response format from the camera is:

“:”, ASK, “RR”,[data] (12 x 2 bytes ASCII), CR

2.Report from pages “RP 0-6” command. Camera responds:

“:”, ASK, “P”, “0-6” (page), (12 x 2 bytes ASCII), CR

3.Report from user calibration table “R U”, “A-D” command. Camera response is: “:”, ACK, “U”, “A-D”, [data] 5 x 2 bytes (first five value above twelve value)

4.Report from factory set “R S”, “A-D” command. Camera response is:

“:”, ACK, “S”, “A-D”, [data] 5 x 2 bytes (first five value above twelve value)

1

2

3

4

5

 

6

7

 

8

9

10

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

8

8

8

8

 

8

8

 

8

8

8

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Main Gain

(ch. A and ch. B)

 

 

7.

Video voltage reference top

2.

Ch. A fine tune gain

 

 

 

 

 

8.

Reserved

3.

Ch. B

fine tune gain

 

 

 

 

 

9.

Function flag

4.

Ch. A video voltage reference

 

10. Shutter dial switch valve

5.

Ch. B

video voltage reference

 

11. Normal shutter value

6.

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

Bit

Function Flag Description

7

6

5

4

3

2

1

0

Bit

Description

 

 

0

Clock Selection

1- 60 Hz

0- 120 Hz

1

Sync Output

1- “One Shot”

0- Continuous

2

Shutter

1- On

0- Off

3

Shutter Control

1- Direct

0- Normal

4

Async Mode

1- Pulse Width

0- Normal

5

Shutter Mode

1- Async

0- Normal

6

Partial Scan 0

11- 120 Hz

01-200 Lines

7

Partial Scan 1

10- 100 Lines

11- N/A

For detailed parameters, please contact PULNiX.

Command C

Pixel Clock Speed (frame rate 120/60Hz)

Clock/2:

“:”, “C”, “1”, CR

 

3AH, 43H, 31H, 0DH

Master Clock:

“:”, “C”, “0”, CR

 

3AH, 43H, 30H, 0DH

Note: When RS-232C is active, back plate switches are overwritten and do not function. In order to activate back plate switches, power off and power up again.

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

Image 27
Contents TM-6710/6710CL High-Speed Progressive Scanning CCD Camera Page TM-6710/6710CL High-Speed Progressive Scanning CCD Camera WarrantyCertifications CE CompliancePage Ii Table of Contents InstallationIii List of Figures Features IntroductionProduct Description Applications IntroductionTM-6710 System Configuration Introduction System ConfigurationGetting Started Unpacking Instructions InstallationInstallation Accessories and OptionsInstallation Camera Setup Pin Configurations 1 a 12-Pin Connector TM-67101 b 12-Pin Connector TM-6710CL Camera Link Connector 1 c 51-Pin ConnectorMDR 26-Pin Connector 0226-622VC Power Supply and Power Cable SetupCS-232-B912 3 RS-232 Cables and Connectors TM-6710 onlyBack-Focusing the Lens Attaching the Video Output Analog Output on TM-6710 OnlyAttaching the Camera Lens Rear Panel OperationOperation Dual-Tap Video OutputRear Panel Layout TM-6710CL Pin Power Operation Mode Control Switches TM-6710 Mode Control Switch Up/Down SwitchModes of Operation Shutter Operation Shutter Control Asynchronous Reset with ShutterExternal Sync Input Schematic Operation External SynchronizationVinit Input Schematic External Pulse Width Control ModeInternal Slow Reset Mode Internal Fast Reset ModeIntegration Partial Scan ModeProgressive scanning quad speed output normal mode RS-232C Communication Default ConditionOperation Progressive Scanning Async Shutter Mode RS-232C Control CommandsCommand S Manual Shutter ModeCommand Command GCommand W Command LCommand R Command C Report from pages RP 0-6 command. Camera responds1st Char 2nd Char RS-232C Control Commands Summary TableTiming Operation Video OutputPixel Clock Frame Data ValidCamera Timing Charts Camera Timing ChartsAsync Reset Timing 38 P, 1.49 µsec H, 6 µsec 254 H, 8.33 msec 5 H, 147.6 µsec Troubleshooting Troubleshooting Information and Support Resources Appendix SpecificationsSpecifications Table AppendixTM-6710 Physical Dimensions Glass Specifications TM-6710 Block Diagram Appendix Block DiagramsPage Email imaging@jaipulnix.com