Page 12
Operation
3.2.1Mode Control Switches (TM-6710)
Mode | Control Switch | Up/Down Switch |
|
0 | Normal mode |
|
|
1 | Gain control (A/B) | up - increase gain of Ch. A |
|
|
| down - decrease gain of Ch. A | |
2 | Gain (A/B) fine tune | up - increase gain of Ch. A |
|
|
| down - decrease gain of Ch. A, while decrease/increase gain of Ch. B, | |
|
| at 5:1 ration |
|
3 | Main Vref control | up - increase gain of Ch. A |
|
|
| down | |
4 | Vref balance control | up - increase gain of Ch. A |
|
|
| down - increase/decrease A/D voltage reference of Ch. A, while | |
|
| decrease/increase gain of Ch. B | |
5 | Gain selection | up: 9dB | down: 12dB |
6 | Gain selection | up: 18dB | down: 22dB |
7 | Clock selection | up: 120Hz | down: 60Hz |
8 | Async/Manual shutter | up: Manual | down: Async |
9 | Factory set recall | up/down - recall only |
|
A | Power up (recall or save) | up: recall | down: save |
User page storage (store | up: recall | down: save | |
| user settings) |
|
|
D | Direct shutter | up - increase manual shutter speed | |
|
| down - decrease manual shutter speed | |
E | Partial scan | up: 100 lines | down: |
F | Partial scan | up: normal scan | down: 200 lines |
3.3 Modes of Operation
3.3.1Shutter Operation
The
Note: Some slow speed shutter rates will not apply to partial scanning.