CV-A50 / CV-A60
7.2. CV-A50/60 RS-232C command list.
|
| Command Name | Format | Parameter |
| Remarks | |
| A – | General settings and useful commands |
|
|
| ||
EB |
| Echo Back | EB=[Param.]<CR><LF> | 0=Echo off | 1=Echo on | Off at power up | |
ST |
| Camera Status request | ST?<CR><LF> |
|
| Actual setting | |
HP |
| Online Help request | HP?<CR><LF> |
|
| Command list | |
VN |
| Firmware version | VN?<CR><LF> |
|
| 3 letter version | |
| B – Timing and shutter related commands |
|
|
| |||
SC |
| Scanning format | SC=[Param.]<CR><LF> | 0=Interlaced | Partial scanning is | ||
|
|
|
|
| 2=1/2 partial | 3=1/3 partial | not supported |
TR |
| Trigger mode | TR=[Param.]<CR><LF> | 0=normal | 1=Edge |
| |
|
|
|
|
| 2=Pulse width | 3=Frame delay |
|
|
|
|
|
| 4=Long time | 5=Start/stop |
|
SM |
| Shutter mode | SM=[Param.]<CR><LF> | 0=Normal | 1=Programmab. |
| |
SH |
| Shutter speed | SH=[Param.]<CR><LF> | 0=Off | 1=1/100 | Continuous only | |
|
|
|
|
| 0=1/50 (1/60) | 1=1/125 | Trigger modes and |
|
|
|
|
| 2=1/250 | 3=1/500 | Continuous |
|
|
|
|
| 4=1/1000 | 5=1/2000 |
|
|
|
|
|
| 6=1/4000 | 7=1/10000 |
|
PE |
| Programmable expos. | PE=[Param.]<CR><LF> | 0= No function | 1=1.5H | CCIR. H=64µsec | |
|
|
|
|
| 1023=1023.5H |
| EIA, H=63.5µsec |
|
|
|
|
|
|
| *1) |
| C – Signals and polarity |
|
|
|
| ||
FR |
| Accumulation | FR=[Param.]<CR><LF> | 0=Field | 1=Frame |
| |
PC |
| Pixel clock | PC=[Param.]<CR><LF> | 0=no clock out | 1=clock out | Should be off | |
|
|
|
|
|
|
| when not used |
TP |
| Trigger polarity | TP=[Param.]<CR><LF> | 0= active low | 1= active high | *2) | |
WP |
| WEN polarity | WP=[Param.]<CR><LF> | 0= active low | 1= active high |
| |
| D – Gain and analogue signals setting |
|
|
| |||
AS |
| AGC Switch | AS=[Param.]<CR><LF> | 0=AGC off | 1=AGC on | 0= manual gain | |
AG |
| AGC Level | AG=[Param.]<CR><LF> | 0=low | 255=high | Range 0 to 255 | |
GA |
| Manual gain Level | GA=[Param.]<CR><LF> | 0=low | 255=high | Range 0 to 255 | |
RP |
| Rear Potentiometer | RP=[Param.]<CR><LF> | 0=manual gain | 1=rear potm. |
| |
SU |
| Setup Level | SU=[Param.]<CR><LF> | 0=low | 255=high | Range 0 to 255 | |
WC |
| White clip Level | WC=[Param.]<CR><LF> | 0=low | 255=high | Range 0 to 255 | |
GS |
| Gamma Select | GS=[Param.]<CR><LF> | 0=gamma 1 | 1=gamma 0.45 |
| |
| E – Saving and loading data in EEPROM |
|
|
| |||
LD |
| Load settings from | LD=[Param.]<CR><LF> | 0=Factory data | 1=User 1 area | Latest used data | |
|
| camera EEPROM |
| 2=User 2 area | 3=User 3 area | area becomes | |
|
|
|
|
|
|
| default at next |
|
|
|
|
|
|
| power up |
SA |
| Save settings to | SA=[Param.]<CR><LF> | 1=User 1 area | 2=User 2 area |
| |
|
| camera EEPROM |
| 3=User 3 area |
|
|
*1) In normal non trigger mode (TR=0) PE<312 for CCIR and PE<262 for EIA. In trigger mode TR=1, EEN will not be correct if PE>833.
*2) If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.
!!Do not try to use commands not shown in the list.