JAI CV-A60, CV-A50 Start/Stop Mode, Start/stop mode. Interlaced with frame accumulation

Page 17

CV-A50 / CV-A60

6.9. Start/Stop Mode

The exposure time is controlled by the interval between the ext. trigger and the ext. VD signal. The exposure starts at the first HD pulse after the falling edge of the ext. trigger, and stops 14.5 H after the falling edge of the VD pulse. It means that the trigger pulse must be applied after the external VD pulse, for exposures less than 14.5 H. The range can be between 1/60 to 1/10,000 for EIA, and 1/50 to 1/10,000 for CCIR. The Start/Stop mode is a continuous mode where the VD signal must be given continuously. It is not possible to input external VD randomly. The difference between interlaced frame accumulation or field accumulation can be explained as follow.

Both modes have 2 fields output in an interlaced frame. With frame accumulation, the contents in the ODD and EVEN sync fields will come from sensing field 1 and 2 on the CCD sensor. With field accumulation both ODD and EVEN sync fields will contain the signal from sensing field 1 and 2 added together.

Non-interlaced with field accumulation needs only 1 trigger pulse for each field.

To use this mode:

 

 

Set function:

Trigger mode to “Start/Stop”

TR=5

 

Accumulation to “Field” or “Frame”

FR=0, F=1

 

Scanning to “Interlaced”

SC=0

 

Polarity and other functions

 

Input:

Ext. VD to pin 7 on 12 pin connector.

 

 

Ext HD to pin 6 on 12 pin connector.

 

Fig. 25a. Start/stop mode. Interlaced with frame accumulation.

Fig. 25b. Start/stop mode. Interlaced with field accumulation.

ext. Trig

13H

ext. HD

ext. VD

Accum

com posite

video

accum ulation

stops here

Min. accum .

Fig. 26. Start/Stop timing details.

- 16 -

Image 17
Contents CV-A50 / CV-A60 CV-A50 / CV-A60 Table of ContentsStandard Composition Main FeaturesGeneral Camera Housing and Dimensions Pin Assignment Pin Multi-connector DC-IN/VIDEO OUT, EXT.HD/VDPin Multi-connector Trigger and RS232C Video output Input and Output CircuitsTrigger input HD and VD inputBasic functions Functions and OperationsContinuous Operation Non triggered Input-output of HD/VD SignalsCV-A50 / CV-A60 Vertical timing details for interlaced. Ccir Vertical timing details for interlaced. EIA Start/stop Mode. TR=5 External Trigger ModesImportant notes on using this mode Edge Pre-select ModePulse width control Ccir Pulse Width Control ModePage Long time exposure. Field accumulation Long Time Exposure ModeStart/stop mode. Interlaced with frame accumulation Start/Stop ModeOther Functions RS-232C control Configuring the CameraTiming and shutter related commands CV-A50/60 RS-232C command listCamera Control Tool for CV-A50/60 1 HD/VD input-output selection Internal Switch and Jumper SettingsSelecting termination of HD/VD input signals CV-A50C CV-A50E CV-A60C CV-A60E SpecificationsCV-A50 or CV-A60 emulating CV-M50 interfacing Spectral SensitivityAppendix CV-A50/60 without sync on video output WEN out on pin 6 on 6 pin connectorTypical CCD Characteristics PrecautionsCamera type CV-A50/60 Users Record